The HACCP report
A summary of the product core temperature settings will be
printed out in hourly blocks. The cycle time (5, 10 or 15 min)
is indicated after the information on the time.
Press and hold the Right-Select button to print the reports from
the report selected to the latest ("000") report (day or week
overview).
The data can also be exported to a PC as a text file. ´To do this,
start up a terminal program installed in the PC (e.g.
hyperterminal ).
Set nominal
time
Time at the
nominal temperature
Core
temperature
Nominal value
Cooking
mode
Step No.
Minimum and
maximum
temperature for this
step
Settings
Special
events
Serial No.: 01234567
Appliance model: 6.1
Date of printout: 23.06.2003
Abbreviations: CM = Cooking mode,
S = Moist, CD = Combi steaming,
HC = Dry Heat R = Rethermalization,
CT = Core temperature
Cooking program: Right
Cooking date: 19.06.2003 8:59
End: 10:38
Cooking time: 1:39
Temp Time
No. CM Min, Max CT Nominal
Actual
1 S 96, 133 - 1:00 0:49
2 CS 99, 99 75 - 0:00
3 CS 99, 161 85 - 00:11
4 CS 157, 179 90 - 00:06
5 HC 179, 199 95 - 0:27
Core temperature values
8:59 45, 25, 30, 38, 45, 52 5 min.
58, 62, 68, 72, 75, 78 5 min.
09:58 82, 84, 89, 92, 93, 94 5 min.
94, 95 5 min.
Door was opened
Summary of Contents for ECS-605
Page 2: ......
Page 4: ......
Page 10: ...Operating Manual Contents 10 ...
Page 12: ...Electric Space aver 12 Space aver Appliance description ...
Page 29: ...Operation Electric Space aver 29 Space aver ...
Page 30: ...Electric Space aver Operation 30 Space aver ...
Page 50: ...Electric Space aver 50 Additional functions Space aver 50 ...
Page 51: ...Electric Space aver 51 Additional functions Space aver ...
Page 52: ...Electric Space aver More functions 52 Space aver ...
Page 60: ...Electric Space aver Practical tips 60 Space aver ...
Page 73: ......