Model EEG-241, 242, 243, 244
36
Aug. 2014
5-5. STATS MODE
This mode allows a technician to view advanced information on
the operation of the fryer and controls.
1. Press and hold the button for 5 seconds until “LEVEL
2”, followed by, “SP PROG” and “ENTER CODE” show in
the display.
2. Press the button 5 times and “STATS” and “ENTER
CODE” flash in
the left display.
3.
Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first 2 product buttons).
4.
“ST-1 STATS LAST RESET ON...” flashes in the left dis
-
play and the date shows in the right display. Use the
◄ and ► buttons to select the steps.
ST-1 •
Stats Last Reset Date
ST-2
• Fryer Total Running Hours
S
T-3
• Left Vat Melt Cycle Hours
ST-4
• Left Vat Cook Cycle Hours
ST-5
• Left Vat Idle Hours
ST-6
• Right Vat Melt Cycle Hours
ST-7
• Right Vat Cook Cycle Hours
ST-8
• Right Vat Idle Hours
ST-9
• Power-Ups Count
ST-10
• Error Counts
ST-11
• Left Vat Heat On Hours
ST-12
• Right Vat Heat On Hours
ST-13
• Highest Left Vat Oil Temperature
ST-14
• Highest Right Vat Oil Temperature
ST-15
• Highest CPU Temperature
ST-16
• System RAM Fade Count
ST-17
• Cook RAM Fade Count
ST-18
• Product RAM Fade Count
ST-19
• Stat RAM Fade Count
ST-20
• RAM Data Error Count
ST-21
• Data Total Loss Count
ST-22
• User Intialization Count
ST-23
• Automatic Initialization Count
ST-24
• Cooks Count per Product
ST-25
• Cook Cycle Stop Counts
- “A” = number of stops in the first 30 sec.
- “B” = 0
- “C” = 0
- “D” = complete cook cycles counted
ST-26
• Reset All Stats
If a bad code is entered, a tone sounds and “BAD CODE”
shows on the display. Wait a few seconds, the controls
revert back to the cook mode, and repeat the above steps.
Press and hold button at anytime to return to normal oper-
ation.