Aug. 2014
This section provides checkout and replacement procedures,
for various parts of the fryer. Before replacing any parts, refer
to the Troubleshooting Section to aid you in finding the cause
of the malfunction.
1. A multimeter will help you to check the electric
components.
2. When the manual refers to the circuit being closed, the
multimeter should read zero unless otherwise noted.
3. When the manual refers to the circuit being open, the
multimeter should read infinity.
Do not move the fryer with hot oil in the vat or filter pan.
Severe burns can result from splashing hot oil.
To ensure a long life of the fryers and their components, regular
maintenance should be performed. Refer to the chart below.
SECTION 6. MAINTENANCE
6-1. INTRODUCTION
6-2. MAINTENANCE
HINTS
6-3. PREVENTIVE
MAINTENANCE
Frequency
Action
Daily
Filter the oil (See Daily
Filtering Instructions Section in
Operator’s Manual)
Daily
Change Filter Pad (See
Changing Filter Pad Section in
Operator’s Manual)
Every filter pad change
Lubricate filter pan o-rings
Quarterly
Inspect/Change Filter Pan
O-Rings (See Check/Replace
Filter Drain Pan O-Ring
Section)
When oil smokes, foams-up
violently, or tastes bad
Change oil
Every change of oil
Clean Vat (See Clean-Out Mode
Section in Operator’s Manual)
Semi-Annually
Clean blowers & Vents (See
Section 3-21 in Operator’s
Manual)
Summary of Contents for EVOLUTION ELITE EEG-241