Service menu - appliance test
23
Service instructions
5.6 WaveClean test
Overview
Description
WaveClean test program for function check.
Circulation pump
Siphon pump
Magnetic valve for water filling
Door seal / leak tightness in door area
INFORMATION
Follow the instructions on the touch screen.
The test is used exclusively for functional testing and not to clean the cooking
chamber.
Starting the test
Touch the "START" field.
Checking of the cooking chamber temperature.
Automatic cooling off of the cooking chamber if > 70°C.
Rinse and fill up siphon.
Draining by pump G24.
Filling by magnetic valve K12.
Circulation and heating.
The circulation pump G16 is switched on.
Heating of the cooking chamber to 55°C.
Rinse DynaSteam and siphon
DynaSteam steaming unit is switched on.
Another water change from the siphon.
After 30 minutes, the WaveCleanTest ends.
Canceling the test
An abortion is possible at any time.
Touch the "STOPP" field.
Automatic rinsing of the siphon and test cancellation.
FM06-078A