Service menu - appliance test
35
Service instructions
5.23 Settings parameters
5.23.1 Selecting and changing parameters
Description
Querying and setting additional parameters.
Overview
Selecting parameters
Selecting parameters by adjusting the roller.
Tap the "Read" field.
Display of set parameters.
Changing parameters
Use the number block to set the desired values by tapping.
Tap the "Write" field.
Changes saved.
5.23.2 Parameter overview
No.
Basic setting
Standard
value
Range of
adjustment
Explanation
7
User menu password
111
0 - 300
Password for the user menu (basic settings)
16
Cooking chamber temperature
offset
-9.9 - +9.9°K
Ability to retrieve the saved temperature offset
values. The can also be changed and saved.
The calibration function in the Service menu is
used for calibration!
21
Core temperature offset,
sensor 1
-9.9 - +9.9°K
22
Core temperature offset,
sensor 2
-9.9 - +9.9°K
23
Core temperature offset,
sensor 3
-9.9 - +9.9°K
24
Core temperature offset,
sensor 4
-9.9 - +9.9°K
45
Generator mode
0
0 = Off
1 = On
Only when using generators on ships.
48
Steam elimination mode
1
0 = Low
1 = Normal
2 = High
"Low" setting: Minimum water consumption,
but higher condensate temperature and
greater steam volume. "High" setting:
Maximum water consumption, but lower
condensate temperature and smaller steam
volume.
49
Controls the cooking chamber
lamp when opening the
cooking chamber door
0
0-60 seconds
FM06-078A