10.4 Water vapor sensor defective (710)
Description
Emergency operation is activated automatically and displayed. The
software controls the water vapor elimination.
Location
The water vapor sensor is on the rear side of the siphon.
Naming on the circuit
diagram
B4
Troubleshooting
Unlatch and open the operating panel.
Check contacting on control board A1, X27.
Remove existing water vapor sensor from the control board A1,
X27 and plug in new water vapor sensor.
The fault message disappears. Replace water vapor sensor.
To do this, remove the left side wall.
The fault message is still displayed. Replace control board.
FM06-078A