Error messages
60
Service instructions
10.9 Fan defective. Cooking program was cancelled (701)
Description
The control board A1 does not receive any response via the CAN bus
cable from power board T10.
Troubleshooting
10.10 FAN_ID23: Fan error: Attempt to restart
10.10.1 Overview
w
PE
L1
N
v
u
a
b
c
d
e
f
g
a Fuse F1 6.3 A
b Power board
c Connector S300. Motor power
supply
d Connector S100. Power supply
circuit board
e Connector S500. CAN connection
to control circuit board
f Connector S501. Input for
temperature switch from motor
10.10.2 Troubleshooting
DANGER
Warning: electric shock! Danger of death!
When working on the power board, make sure that energized parts are ex-
posed. Work on these components during operation and up to 3 minutes after
enabling is not allows. Even if the motor is stopped and the appliance is de-en-
ergized, the connection terminals and components can conducted dangerous
voltage!