Model HCH-930/932
2-11. HEATER
1. Disconnect the electrical supply to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
2. Remove the cabinet top.
3. Remove the 2 screws securing the high limit to the heater, and pull
Step 5
high limit from heater.
4. Remove the 2 wires attached to the heater terminals.
5. Remove the 2 screws securing the heater to the heater box cover,
and remove heater from unit.
6. Install new heater in reverse order.
7. Reconnect electrical supply to the cabinet.
2-12. HIGH LIMIT
1. Disconnect the electrical supply to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
2. Remove cabinet top.
3. Remove the 2 wires attached to the high limit.
4. Check for continuity across the 2 terminals of the high limit. As
long as the temperature of the cabinet is below 210
o
F (99
o
C),
and the blower is operating properly, the high limit should be
closed. If the high limit is defective, continue with the following
steps.
5. Remove the 2 screws securing the high limit to the heater, and pull
high limit from heater.
Step 5
6. Install new high limit in reverse order.
7. Reconnect electrical supply to the cabinet.
203
2-7
Summary of Contents for HCH-930
Page 1: ...TECHNICAL MANUAL Henny Penny Heated Holding Cabinet Model HCH 930 Model HCH 932...
Page 2: ......
Page 4: ...ii 703...
Page 8: ...Model HCH 930 932 THIS PAGE INTENTIONALLY LEFT BLANK 1 4 703...
Page 21: ...Model HCH 930 932 807 2 13 2 20 WIRING DIAGRAMS...
Page 22: ...Model HCH 930 932 2 14 807 2 20 WIRING DIAGRAMS Continued...
Page 23: ...Model HCH 930 932 807 2 15 2 20 WIRING DIAGRAMS Continued...