Model HCH-930/932
2-1. INTRODUCTION
This section provides procedures for the checkout and replacement
of the various parts used in the cabinet. Before replacing any parts,
refer to the Troubleshooting section. It will aid you in determining the
cause of the malfunction.
2-2. MAINTENANCE HINTS
1. You may want to use a multimeter to check the electric
components.
2. When the manual refers to the circuit being closed, the
multimeter should read zero unless otherwise noted.
3. When the manual refers to the circuit being open, the multimeter
will read infinity.
2-3. DELIMING WATER PAN
Inspect the water pan and baffles every 10 days for lime buildup,
AND BAFFLES
and clean when necessary.
Failure to keep the water pan and baffles free of lime
buildup reduces the performance of the cabinet.
1. Disconnect the electrical supply to the cabinet.
Failure to disconnect power to the cabinet causes the
interior of the cabinet to be “flooded” with water from
the automatic water fill system.
2. Remove the top drawer from the cabinet.
3. Remove the water pan and baffles by supporting the pan with one
hand and pulling out on the latches with the other hand. The
water pan drops down from the ceiling.
4. Remove the 4 baffles from the water pan.
Step 3
705
2-1
SECTION 2. MAINTENANCE
Summary of Contents for HCH-930
Page 1: ...TECHNICAL MANUAL Henny Penny Heated Holding Cabinet Model HCH 930 Model HCH 932...
Page 2: ......
Page 4: ...ii 703...
Page 8: ...Model HCH 930 932 THIS PAGE INTENTIONALLY LEFT BLANK 1 4 703...
Page 21: ...Model HCH 930 932 807 2 13 2 20 WIRING DIAGRAMS...
Page 22: ...Model HCH 930 932 2 14 807 2 20 WIRING DIAGRAMS Continued...
Page 23: ...Model HCH 930 932 807 2 15 2 20 WIRING DIAGRAMS Continued...