background image

 

 

 

 

Model MPC-1L, MPC-22, MPC-554

3-6

FM06-038-B

July 2011

 

 To avoid electrical shock or property damage, move the  

   power switch to OFF and disconnect main circuit 

  breaker,  or unplug cord at wall receptacle.

Checkout:

1.  Slide the component panel out as described in the first step 

  in Section 2-3.

 

  To avoid electrical shock, make connections before    

  applying power, take reading, and remove power before  

  removing meter leads.  The following checks are per- 

  formed with the wall circuit breaker closed and the 

  main power switch in the ON position.

 

2.  Remove the relay cover from the relay.  
3.  Refer to wiring diagram page 2-9, and with the outputs on,  

  check across terminal #1 of the appropriate relay and the  

  neutral wire, N5 at the transformer.  If meter shows full 

  voltage (120V), but heater is not heating, the heater and 

  liner assembly must be replaced.

  The heater is sealed to the liner assembly, so the appropri-

  ate  liner and heater assembly must be replaced if the heater 

  is faulty.

Replacement:

4.  Using a Phillip’s-head screwdriver, or a #8 Torx socket   

  (MS01-514), remove the 16 screws   around the perimeter 

  of the enclosure & the 2   screws securing the power cord.  

  Figure 1.

5.  Pull component panel from unit and disconnect the two, 

  white connectors, and remove   component panel from unit.   

  Figure 2.

  

6.  Pull cabinet enclosure from unit.  Figure 3. 

3-7.   MPC-554 LINER/HEATER 

 

ASSY. REPLACEMENT

Figure 1

Figure 2

Figure 3

Summary of Contents for MPC-1L

Page 1: ...TECHNICAL MANUAL Henny Penny Multipurpose Holding Cabinet Model MPC 554 Model MPC 1L Model MPC 22 FM06 038 B...

Page 2: ......

Page 3: ...3 Entering Password 2 1 2 4 Programming Descriptions 2 2 Section 3 MAINTENANCE 3 1 3 1 Introduction 3 1 3 2 Maintenance Hints 3 1 3 3 Control Board Replacement 3 1 3 4 Transformer Replacement 3 2 3 5...

Page 4: ...ed power cord with the ground wire dimensioned to fail last If the supplied power cord or an existing one becomes damaged do not use it rather replace it with a known good power cord The power cord mu...

Page 5: ...r or replacement of a part EXTENDED FRYPOT WARRANTY Henny Penny will replace any frypot that fails due to manufacturing or workmanship issues for a period of up to seven 7 years from date of manufactu...

Page 6: ...the proper procedures Where information is of particular importance or is safety related the words DANGER WARNING CAUTION or NOTICE are used Their usage is described as follows DANGER indicates a haz...

Page 7: ...arly define the problem or symptom and when it occurs 2 Locate the problem in the troubleshooting table 3 Review all possible causes Then one at a time work through the list of corrections until the p...

Page 8: ...e polarity of 5 vdc to relay reference wiring diagram 3 If voltage varies from steps 1 and 2 remove power to unit pull input wires from relay and place leads of meter onto input wires Reapply power to...

Page 9: ...t cut power to relay when the faulty relay or LED is green then replace control board but control board if control board does cut power to relay when the LED is green but unit continues to heat check...

Page 10: ...WORD After accessing Special Programming Mode CodE displays and then 0 displays 1 Use the UP DOWN buttons once to increment the number to 1 2 Once the correct number displays press the P button to sel...

Page 11: ...oard temperature displays 8 Outputs test 1 Use the DOWN button to toggle the heat outputs on off 2 Use the UP button to move on to the next step 3 Use the DOWN button to toggle each of the other three...

Page 12: ...rd at wall receptacle 1 Locate the control access panel on the side of the unit and using a Phillip s head screwdriver or a 8 Torx socket re move the 2 screws securing the panel Figure 1 Slide panel o...

Page 13: ...securing the control board or the buttons on the controls may not function To avoid electrical shock or property damage move the power switch to OFF and disconnect main circuit breaker or unplug cord...

Page 14: ...power switch to OFF and disconnect main circuit breaker or unplug cord at wall receptacle 1 Slide the component panel out as described in the first step in Section 2 3 Checkout To avoid electrical sh...

Page 15: ...t wires from relay and place leads of meter onto input wires Reapply power to unit When unit is running if the input wires to relay shows 5vdc the relay is faulty 6 Uplug power cord to unit 7 Label an...

Page 16: ...3 Label and remove the wires from the switch Check for continuity across the top and bottom terminals With the switch in the ON position the circuit should be closed With the switch in the OFF positi...

Page 17: ...diagram page 2 9 and with the outputs on check across terminal 1 of the appropriate relay and the neutral wire N5 at the transformer If meter shows full voltage 120V but heater is not heating the hea...

Page 18: ...5 nuts on the rear of the front panel Figure 4 8 Using a 1 8 drill bit drill out the pop rivets securing the bottom of the front panel and then remove front panel from unit Figure 5 9 Remove the scre...

Page 19: ...p rivets pop rivet the liners to the side bottom liner supports if needed 3 on each side 12 Using the screws removed in step 6 secure the liner to the liner supports and then pop rivet the front panel...

Page 20: ...Model MPC 1L MPC 22 MPC 554 3 9 FM06 038 B June 2011 3 9 WIRING DIAGRAMS MPC 554...

Page 21: ...Model MPC 1L MPC 22 MPC 554 3 10 FM06 038 B July 2011 HEATER OHM READINGS ROOM TEMP MIN NOM MAX MPC 1L 124 36 130 91 137 45 MPC 22 68 40 72 00 75 60...

Page 22: ...u of the cost of your parts order 3 5 DELIVERY Commonly replaced items are stocked by your local distributor and will be sent out when your order is received Other parts will be ordered by your distri...

Page 23: ...038 B July 2011 MPC 554 MPC 1L MPC 22 Item No Part No Description Quantity B 1 30978 Transformer Assembly 120VP 12VS 20VP 1 A 2 40645 Relay 25A Solid State As Required B 3 73602 Control MPC 1 Recomme...

Page 24: ...64 Switch Power 1 1 1 A 9 LS72 000 Indicator Bi Color Panel Mount 1 1 1 10 69608 Decal Control MPC 554 MPC 1L MPC 22 1 1 1 11 88814 Decal Power Switch MPC 22 1 1 12 ME50 021 Terminal Block MPC 554 not...

Page 25: ...er 230V 1 91996 003 Assy MPC1L Liner 100V 1 165496 001 Assy MPC1L Liner 120V 1 165496 002 Assy MPC1L Liner 230V 1 165496 003 Assy MPC1L Liner 100V 1 28979 Transformer 208 240VP 12VS 1 1 165535 001 Ass...

Page 26: ...Henny Penny Corporation P O Box 60 Eaton OH 45320 1 937 456 8400 1 937 456 8402 Fax Toll free in USA 1 800 417 8417 1 800 417 8434 Fax www hennypenny com Revised October 2018 FM06 038 B...

Reviews: