Model 290
This high temperature control is a safety, manual reset control,
which senses the temperature of the shortening. If the shortening
temperature exceeds 425°F (218°C), this switch opens and shuts
off the heat to the frypot. When the temperature of the shortening
drops to a safe operation limit, manually reset by pressing the red
reset button. The red reset button is located under the control
panel, in the front of the fryer, to the right of the drain. Once reset,
the frypot starts heating.
Checkout
Before replacing a high temperature limit control, check to see
that its circuit is closed.
The shortening temperature must be below 380°F (193°C) to
accurately perform this check.
1. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel.
3. Remove the inner heat shield.
4. Remove the two nuts securing the high limit bracket to the unit,
and pull the bracket from the unit.
5. Remove the two screws securing the high limit to the bracket,
and remove the high limit from the bracket.
6. Remove the two electrical wires from the high temperature
limit control.
7. Manually reset the control, then check for continuity between
the two terminals after resetting the control. If the circuit is
open, replace the control, then continue with this procedure. (If
the circuit is closed, the high limit is not defective. Reconnect
the two electrical wires.)
1103
2-2
2-4. HIGH TEMPERATURE
LIMIT CONTROL
Summary of Contents for OFE-290
Page 1: ...Henny Penny Open Fryer Electric Model OFE 290 TECHNICAL MANUAL ...
Page 2: ......
Page 31: ...Model 290 104 2 18 ...
Page 32: ...Model 290 2 19 104 ...
Page 33: ...Model 290 104 2 20 ...
Page 34: ...Model 290 2 21 104 ...
Page 35: ...Model 290 104 2 22 ...
Page 36: ...Model 290 2 23 104 ...
Page 37: ...Model 290 104 2 24 ...
Page 40: ...Model 590 1203 3 3 Figure 3 1 Frame and Cover Assembly ...
Page 47: ...Model 590 3 7A FILTER PUMPASSEMBLY SN LG012JC BELOW 3 10 1203 Pump Interior ...
Page 49: ...Model 590 3 7B FILTER PUMPASSEMBLY SN LG013JC ABOVE 3 12 1203 Pump Interior ...
Page 52: ...Model 590 1203 3 15 3 9 DRAIN PAN AND FILTER ASSEMBLY ...