Model 290
The
temperature probe relays the actual shortening temperature to
the control. If it becomes disabled, “E06” shows in the display.
Also, if the temperature is out of calibration more than 10°F, or
10°C, the temperature probe should be replaced as follows:
1. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Drain the shortening from the frypot.
3. Remove the control panel.
4. Using a 1/2" wrench, remove the nut on the compression fitting.
5. Remove the temperature probe from the frypot.
6. Place the nut and new ferrule on the new temperature probe and
insert the temperature probe into the compression fitting until it
extends one-half (1/2) inch (1.3 cm) into the frypot. Use the
temperature probe gauge provided in the temperature probe kit,
to ensure proper placement in frypot. See Figures 2-1 and 2-2.
7. Tighten hand tight and then a half turn with wrench.
Excess force will damage temperature probe.
8. Connect new temperature probe to PC board and replace
control panel.
9. Replace shortening.
10. Turn power on and check out fryer.
1103
2-6
Figure 2-1
2-7. TEMPERATURE PROBE
REPLACEMENT
Figure 2-2
Summary of Contents for OFE-290
Page 1: ...Henny Penny Open Fryer Electric Model OFE 290 TECHNICAL MANUAL ...
Page 2: ......
Page 31: ...Model 290 104 2 18 ...
Page 32: ...Model 290 2 19 104 ...
Page 33: ...Model 290 104 2 20 ...
Page 34: ...Model 290 2 21 104 ...
Page 35: ...Model 290 104 2 22 ...
Page 36: ...Model 290 2 23 104 ...
Page 37: ...Model 290 104 2 24 ...
Page 40: ...Model 590 1203 3 3 Figure 3 1 Frame and Cover Assembly ...
Page 47: ...Model 590 3 7A FILTER PUMPASSEMBLY SN LG012JC BELOW 3 10 1203 Pump Interior ...
Page 49: ...Model 590 3 7B FILTER PUMPASSEMBLY SN LG013JC ABOVE 3 12 1203 Pump Interior ...
Page 52: ...Model 590 1203 3 15 3 9 DRAIN PAN AND FILTER ASSEMBLY ...