Model 290
Problem
Cause
Correction
POWER SECTION
With switch in
•
Open circuit
•
Check to see that unit is
POWER position,
plugged in
the fryer is com-
•
Check the breaker or fuse
pletely inoperative
at supply box
(NO POWER)
•
Check voltage at wall
receptacle
•
Check MAIN POWER
switch; replace if defective
•
Check cord and plug
• Check 15 amp fuses
1203
1-6
•
Blown fuse or tripped
•
Reset breaker or replace fuse
circuit breaker at supply
box or control panel
•
Blown fuse in PC board
•
Replace glass fuse in board
•
Faulty POWER/PUMP switch.
•
Check POWER/PUMP switch
per maintenance section on
the POWER/PUMP switch
•
Faulty cord and plug
•
Check cord and plug
• Check power at receptacle
•
Faulty drain switch
•
Check drain switch per
maintenance section on
drain switches
•
Faulty PC Board
•
Remove and replace control
panel
•
Faulty high limit control switch
•
Check high limit control
switch per maintenance
section on the high limit
•
Drain valve open
•
Close drain valve
•
Possible faulty temperature probe
•
Replace temperature probe
•
Faulty contactor
•
Check contactor per maintenance
section on contactors
HEATING OF SHORTENING SECTION
Shortening will not heat
Summary of Contents for OFE-290
Page 1: ...Henny Penny Open Fryer Electric Model OFE 290 TECHNICAL MANUAL ...
Page 2: ......
Page 31: ...Model 290 104 2 18 ...
Page 32: ...Model 290 2 19 104 ...
Page 33: ...Model 290 104 2 20 ...
Page 34: ...Model 290 2 21 104 ...
Page 35: ...Model 290 104 2 22 ...
Page 36: ...Model 290 2 23 104 ...
Page 37: ...Model 290 104 2 24 ...
Page 40: ...Model 590 1203 3 3 Figure 3 1 Frame and Cover Assembly ...
Page 47: ...Model 590 3 7A FILTER PUMPASSEMBLY SN LG012JC BELOW 3 10 1203 Pump Interior ...
Page 49: ...Model 590 3 7B FILTER PUMPASSEMBLY SN LG013JC ABOVE 3 12 1203 Pump Interior ...
Page 52: ...Model 590 1203 3 15 3 9 DRAIN PAN AND FILTER ASSEMBLY ...