sparking.
OPERATION
Operate with a remote emitter
Button operation:
Button 1: switch to the next color program
Button 2: turns the lamps ON/OFF.
Button 3: turns ON/OFF switch A.
Button 4: turns ON/OFF switch B.
MAINTENANCE
FUSE: In case the lamps suddenly stop working, check incoming and outgoing voltage.
If there is 220V going into the transformer and no 12V coming out, check the fuse and
replace if necessary. This is an indication that there was a spike in voltage that
damaged the fuse.
SPARKING: In case of sparking and/or blackness around the connection terminals,
scrape off all soot, reconnect cables and tighten as much as possible.
REMOTE: In case the remote control stops working or is replaced, there is a small
button on the remote module inside the transformer, press this button for 1 second,
and then immediately press one of the 4 buttons on the remote to pair both devices.
The battery inside the remote may require replacement.
SAFETY WARNINGS
The persons who are in charge of installation should have the required qualifications
for this type of work.
Avoid making contact with the electric voltage.
Comply with the current standards regarding accident prevention.
IEC 364-7-702 standards must be observed: WIRING IN BUILDINGS, SPECIAL
WIRING, SWIMMING POOLS.
Any maintenance works must be performed with the 220V incoming wire disconnected
or switched off at the main supply.
Do not handle any electrical components with wet feet.
AC220V input
12VAC Output
for lights
Switch Output for other
devices, maximum 10A
2
1
3
4
button