SAFETY CONSIDERATIONS 

Read  and  follow  instructions  carefully.  Follow  all  local 
electrical  codes  during  installation.  All  wiring  must 
conform  to  local  and  national  electrical  codes. 
Improper wiring or installation may damage the HEPA 
Air Cleaner. 

Understand  the  signal  words 

WARNING

  and 

CAUTION

  which  are  present  in  the  Owner’s  Manual. 

WARNING 

and 

CAUTION

 signify a hazard which could 

result in property damage, personal injury or death. 

Only a heating/air conditioning installer or qualified 
service  person  should  install,  repair,  or  service 
your Whole-House HEPA Air Cleaner. 
Homeowners  or  untrained  personnel  can  perform 
the  basic  maintenance  functions  of  replacing 
filters. 
When working on air cleaning equipment, observe 
precautions in the Owner’s Manual, labels attached 
to  the  unit,  and  other  safety  precautions  that  may 
apply. Follow all safety codes. Wear safety glasses 
and work gloves. 

WHAT THE HEPA AIR CLEANER DOES 

The  Whole-House  HEPA  Air  Cleaner  has  been 
designed  to  remove  particulate  such  as  atmospheric 
and household dust, coal dust, insecticide dust, mites, 
pollen,  mold  spores,  fungi,  bacteria,  viruses,  pet 
dander,  cooking  smoke  and  grease,  tobacco  smoke 
and more. It also removes odors (with Carbon Prefilter 
and  Carbon  VOC  After  Filter)  and  heavy-duty  odors 
and  fumes  (with  optional  Carbon/Potassium 
Permanganate VOC Filter). 

BENEFITS 

Helps  provide  relief  from  allergies,  asthma,  and 
other respiratory illness. 
Helps reduce housekeeping time and redecorating 
costs. 
Helps  provide  a  healthier,  more  comfortable 
environment, year-round. 

HOW IT WORKS 

Millions  of  airborne  pollutants  are  carried  through  the 
return  air  ducts  of  the  heating/cooling  system.  The 
HEPA Air Cleaner has been designed to be ducted to 
the  return  air  duct.    A  portion  of  this  return  air  is  by-
passed through a 12 inch intake duct on the top of the 
unit and passes through a 3-stage filtration system. 
The  Activated  Carbon  Prefilter  (1  inch  pleated, 
activated  carbon  impregnated  polyester  filter)  first 
removes  lint  and  odors  before  they  enter  the  HEPA 
filter. 

Smaller  particles  then  pass  through  a  long-life,  HEPA 
(High  Efficiency  Particulate  Air)  Filter  which  captures 
99.97%  of  particles  0.3  micron  (1/84,000  of  an  inch) 
and  larger.  This  6  inch  filter  has  more  than  188  ft²  of 
collection surface area. 
Air  is  then  drawn  through  a  Carbon  VOC  (Volatile 
Organic  Compound)  Filter  (2  inch)  to  remove 
unpleasant  odors  and  gases,  or  an  optional  Carbon/
Potassium  Permanganate  VOC  Filter  to  remove 
noxious  odors  and  fumes  like  formaldehyde,  heptane, 
tetrachloroethylene,  toluene,  etc.  that  are  off-gased 
from  carpets,  cabinets,  furniture,  paints,  pesticides, 
personal care products, cleaners, etc. 
Clean  air  is  discharged  through  an  8  inch  duct,  back 
into the return air duct. 

INSTALLATION 

 
 
 
 
 
 
 
 
 
 
 

LOCATION 

The  HEPA  Air  Cleaner  should  be  located  as  close  to 
the return air duct  as possible. This allows for shorter 
lengths of ducting which helps keep the static pressure 
lower.  The unit can be adapted to mount on a wall or 
be  suspended  from  the  ceiling.  Care  should  be  taken 
to  keep  the  unit  away  from  an  area  where  there  is  a 
possibility of moisture leaking on to it. Ensure there is 
36  inches  in  front  of  the  unit  to  remove  the  filters  for 
cleaning or replacing. 

GENERAL INSTALLATION STEPS 

1.  Remove plastic from filters before installing. 
2.  When  the  unit  is  shipped,  the  intake  and  exhaust 

collars are reverse mounted to prevent damage in 
shipping.  The  intake  collar  must  be  removed  and 
reattached  with  the  collar  ring  facing  out.  The 
exhaust  collar  can  be  mounted  on  either  side  of 
the unit with the ring out. The opposite side will be 
covered with the exhaust cover. 

This  cover  must 

be installed for the unit to operate properly.

 

3.  An  inlet  collar  is  provided  on  the  unit  to  allow  a  

 

 

WARNING  

Before  beginning  any  installation  or  modification,  be 
certain  that  the  main  line  electrical  disconnect  switch 
is in the 

OFF

 position. Electric shock could result. Tag 

disconnect switch with suitable warning labels.  

WARNING  

This  unit  must  be  installed  on  the  return  air  side  of 
the system only. Do not connect to supply side. 
Do not install in a cooking area or connect directly to 
any appliance.  

HEPA 

UNIT 

HEATING 

COOLING 

SYSTEM 

RETURN AIR 

SUPPLY AIR 

DEFLECTOR 

AIR CLEANER 

Summary of Contents for RXHEPA5000-ULTRA

Page 1: ...OC After Filter standard removes additional unpleasant odors and gases Heavy duty Carbon Potassium Permanganate VOC After Filter optional upgrade removes noxious odors and fumes emitted from household sources Easy to change filters Heavy gauge steel cabinet and powder coat paint finish provide rigid installation and durability Powerful motor delivers 560 CFM of filtered air Small footprint for eas...

Page 2: ...re they enter the HEPA filter Smaller particles then pass through a long life HEPA High Efficiency Particulate Air Filter which captures 99 97 of particles 0 3 micron 1 84 000 of an inch and larger This 6 inch filter has more than 188 ft of collection surface area Air is then drawn through a Carbon VOC Volatile Organic Compound Filter 2 inch to remove unpleasant odors and gases or an optional Carb...

Page 3: ... the Air Cleaner off when there is no system fan on The unit plugs into a regular 120 volt outlet and is controlled by a switch located on the rear panel near the cord Note Do not allow the cord to be placed where it may be walked on or allow anything to roll over it The door must be secured for the Air Cleaner to operate as the door is interlocked for safety All filters must be in place for the u...

Page 4: ...ers 2 Damage or repairs needed as a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 3 Damage or repairs required as a consequence of faulty installation or application by others 4 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical ser...

Reviews: