6 Parameterinnstilling av Controller Dynamics Rhino II
Program Identification
Name
HS-7 DS120
Identification
10 Km
User Personalization
T
hrott
l
e Configuration
Sleep Timer (min)
30
Throttle Type
Wig-wag
Wake up style
Key Only
Throttle input
Single
Swap Throttle Direction
Yes
Throttle Neutral Offset
0,00
Enable Beeper
Yes
Throttle Full Scale Def
70
Flash Code Beeper
No
Throttle Response (%)
80
Sleep Beeper
Yes
Throttle Dead-band (%)
25
Motion Beeper
None
Throttle Testing
Yes
Beeper On Time (ms)
300
Max Throttle Voltage
4,9
Beeper Off Time (ms)
700
Min Throttle Voltage
0,10
Deep Discharge Beeper
Yes
Throttle OONAPU Voltage
Latching
Sleep on Fault or Inhibit
Yes
Throttle Fault Non Latching
No
Power Off after Sleep
Yes
Speed Limit Pot
No
Slam Break Enable
No
Enable SRW Open Circuit Testing
No
Driver Performance
Profile 1
Profile 2
OEM Drive Limits
Max Forward Speed (%)
e 78
60
Max Forward Speed Limit
100
Forward Acceleration (%)
30
30
Max Reverse Speed Limit
100
Forward Deceleration (%)
55
60
Min Forward Speed Limit
0
Max Reverse Speed (%)
30
30
Min Reverse Speed Limit
0
Reverse Deceleration (%)
40
50
Acceleration Limit (%)
100
Minimum Forward Speed (%)
20
20
Deceleration Limit
100
Minimum Reverse Speed (%)
20
20
Motor Management
Soft Start Period (ms)
800
Motor Protection
No
Soft Finnish (%)
25
Thermal Rollback start
50
Emergency Deceleration (%)
80
Thermal Rollback end
60
Slam Breaking (%)
50
Motor reverse
No
Push Speed (%)
50
Load
Compensation mΩ
45
Roll-away speed (%)
50
Max Load Compensation mΩ
80
SRW Forward Speed Limit (%)
50
Load Compensation Damping (%)
45
SRW Forward Speed Scale (%)
50
Remembered Load Compensation
45
SRW Reverse Speed Limit (%)
50
Current Limit (A)
110
SRW Reverse Speed Scale (%)
50
Boost Current (A)
20
Boost time (s)
2,0
Park Brake Management
Stall Timeout (s)
15
Park Brake Testing
Pre-drive
Motor Testing
Short
Park Brake Neutral Delay (ms)
300
Maximum Motor Voltage (V)
26,2
Park Brake Release Delay (ms)
0,0
Battery management
System Option
Overvoltage Warning (V)
30,2
Service Scheduler
No
Overvoltage Rollback (V)
34,2
Service Period (hours)
5000
Overvoltage Rollback start (V)
19,6
Actuator Time-out (s)
10
Overvoltage Rollback End (V)
17,0
Battery Gauge Minimum (V)
22,0
Battery Gauge Maximum (V)
24,4
Battery Gauge High Warning(V)
29,0
Battery Gauge Low Warning (V)
23,2
Battery Gauge Dead-band (V)
3,5
Battery Gauge Sensitivity
40
Battery Cut-off Voltage (V)
19
Multi-function Input Configuration
Input Pin
Function
Active
Slows to
Latches
Flashes
Pin 4 Function
Slow
Low
50
No
No
Pin 6 Function
None
Low
100
No
No
Pin 12 Function
None
Low
100
No
No
Pin 14 Function
Charger l
Low
100
No
No
Prog/Inh Pin Function
Charger l
Low
100
No
No
Multi-Function Output Configuration
Flash Code Type
Scooter
Pin 3 Function
Beeper
Pin 10 Function
Status High
Pin 11 Function
Brake light
Key Switch Status LED
Yes