Clock, RPM, Wheel, Divider, Unit, Maintenance , Thermometer, fuel meter and ODO

15.  It displays "     1 XXX" and the selected unit. Follow the item 2 of button 
       operation to finish the temperature warning setting and go to 
       thermometer 2 setting. 
16. Thermometer 2 setting  It displays "     2 °C , °F or oFF", each press of 
       RESET button converts °C , °F or Off, the temperature bars will 
       disappear when you select oFF mode; press MODE button to confirm 
       temperature setting and jump to temperature warning setting.
17. It displays "     2 XXX" and the selected unit. Follow the item 2 of button 
       operation to finish the temperature warning setting and go to fuel 
       sensor resistance setting. 
18. It displays “on, off or rES” and      , the setting range of “on” from 10r to 
       990r, press and hold RESET button can change digits quickly, follow the 
       item 2 to select a resistance same as your fuel sender  and jump to 
       sensor type of **LAP timer setting. The fuel meter bar will disappear if 
       you select oFF mode. In “rES” mode connecting the input wire to 0v can 
       bring on the fuel symbol and/or LED indicator instantly. 
19. **It displays Ir, EF1, EF2 or EF3, Ir means you elect IR receiver as the 
       sensor of LAP timer, and the selection of EF1, 2 or 3 is a magnetic field 
       sensor for LAP timer, the number of 1, 2 or 3 is means the number of 
       magnetic sensor in track, for example EF2 means the track has 2 
       magnetic sensor and it will combine 2 sensing signals in one. Follow the 
       item 2 to set sensor type of LAP timer and jump to odometer setting.
20. It displays “ODO & 00000X km”, the “X” is from odometer testing in 
       factory, follow item 2 to setting a desired odometer and jump to clock 
       setting or return to Normal Mode. This setting screen will disappear 
       when the odometer is over 30km (18.6Miles) or your setting is over 
       30km.

       Press 2 Seconds. 

       Mode Button, RESET Button, MODE Reset, Mode + Reset 2 seconds. 

 

1. Setup operations include 12/24hour clock, bar rpm scale, shift warning 
    RPM, numbers of engine signal, wheel circumference, signal divider, 
    units, decimal, maintain reminder, *voltage warning, *units of 
    temperature, *temperature warning, fuel meter input resistance 
    selection, sensor type of **LAP timer  and odometer adjustment. 
    These must be set up step by step. The computer will be automatically 
    revert to normal mode if no button is pressed for 75 seconds at any 
    setting screen. 
2. Press both MODE & RESET buttons to go into setting mode. In setting 
    mode, each press of the RESET button increments the flashing digit by 
    1 or converts units. Press MODE button to confirm the digit setting and 
    jump to next digit or next setting screen to be set. Press MODE button
    for 2 seconds at any setting screen to finish the setting and go to 

    normal mode.

3. It displays "12 or 24H,       and XX:XX-XX" symbols as well AM/PM in 
    case you select 12H. Operates buttons as descriptions of item 2 to 
    finish clock setting and jump to 10,000/20,000rpm scale setting. 
4. It displays 10,000rpm scale, press RESET button to convert 10,000 or 
    20,000rpm. Press MODE button to confirm the setting and jump to 
    shift RPM warning setting.
5. It displays the default "RPM r06500", the digit “0” flash. Follow the 
    item 2 of button operation to finish the shift RPM warning setting and 
    jump to engine specification setting. 
6. It displays "RPM SP 1r1P", the default value is 1r1P; there are 6 
    options: 1r1P, 2r1P, 3r1P, 1r2P, 1r3P, 1r4P. “r” means the numbers of 
    engine rotation, “P” means number of signals from engine. For 
    example the value 2r1P means the engine rotate 2 turns to output one 
    signal.
7. Press RESET button to move in loop sequence from one to another 
    value of the 6 values. Press MODE button to confirm the setting and go 
    to wheel circumference setting screen.
8. In "SPD cXXXX" display, "c" means "Circumference in mm", following 4 
    default digits; flashing digit is digit to be set. Follow the item 2 of 
    button operation to finish the wheel circumference setting and jump 
    to signal divider setting to set the number of pulses from the speed 

    sensor per turn of the wheel.

9. It displays "SPD P-001" for signals to be divided. Follow item 2 of 
    button operation to finish the setting and jump to unit setting. 
10. It displays KM/H or MPH, each press of RESET button converts unit; 
       press MODE button to confirm unit setting and jump to speedometer 
       decimal point setting.
11. It displays “SPD 99.9Km/H” on or “SPD 99Km/H off”, the decimal 
       point will not be displayed when “off” is selected. Follow the item 2 
       of button operation to finish the decimal setting and jump to 
       maintain reminder setting.
12. It displays         and RT, TRIP or OFF. RT has default of 100 hours, TRIP 
       has 1000km (621Miles) default. Follow the item 2 of button 
       operation to finish the maintain reminder setting and jump to 
       voltage warning setting. The maintain reminder function will be 
       disappear when select “OFF”.
13. It displays “        b-on and a flashing numbers of voltage” to be set, 
       “b-on” means battery warning on voltage – when the voltage falls 
       below this the LED will come on, setting range from 11.0 to 14.9V. It 
       displays “        b-off and a flashing numbers of voltage”, “b-off” means 
       battery warning off voltage, setting range from 11.0 to 14.9V to, but 
       b-off voltage must larger than b-on voltage – when this voltage is 
       exceeded the LED will go off. Follow the item 2 of button operation 
       to finish the voltage warning setting and jump to temperature unit 
       setting. 
14. Thermometer 1 setting  It displays "      1 °C , °F or oFF", each press of 
       RESET button converts °C , °F or Off, the temperature bars will 
       disappear when you select oFF mode; press MODE button to confirm 
       temperature setting and jump to temperature warning setting.

**LAP review operations:

1. In the LAP mode, press MODE button to review the 1st storage data, it 

    displays number of lap and lap timer. 

2. Press the LAP button to switch between lap timer or average speed of 

    the same LAP; each press of the MODE button displays data for the next

    lap. 

3. Press and hold LAP buttons for 2 seconds to go out LAP mode and return 

    to normal mode. 

Normal Mode

Lap Mode

Lap Review Mode

Lap

 2 Sec.

Lap

 2 Sec.

Mode

Mode

Mode

Lap

Mode

WHEEL CIRCUMFERENCE TABLE

Tire Size

Circumferen

ce number 

(mm)

Tire Size

Circumferen

ce number 

(mm)

Tire Size

Circumferen

ce number 

(mm)

23 inch
24 inch

25 inch
26 inch

19 inch

20 inch

21 inch
22 inch

15 inch
16 inch
17 inch
18 inch

1835

1915
1995

2075

1516
1596
1676
1756

1197
1277

1357
1436

1. The details below have been calculated using following formula: Tire 
     Diameter (inches) x 25.4(mm/inches) x 3.1416 = wheel circumference 
     (in mm).
2. Identify the tire size (not wheel size) of your ATV/Motorcycle when you 
    need to change different tire size and key in the corresponding number 
    shown in the following chart.    

3. These values are approximate and will differ for different brands of tire, 
    we would always recommend that you measure the distance travelled 
    per revolution of the wheel in mm and enter this into the computer.
4. The computer calculates the wheel rotating length between 2 passes of 
    the magnet; use this table to find the settings when you are using a reed 
    sensor or an universal hall sensor with magnet to measure your speed.
5. If you are using a cable drive speed sensor then enter the number of 
     turns of the speedo cable per turn of the wheel into the “p” screen.
6. You can use more magnets, but the number of magnets must be entered 
    into the “p” screen.
7. The computer has a built-in software divider (“p” screen) setting from 
    1 to 199 for different speed signal application, refer to the divider 
    setup, one means one wheel revolution creates one signal. You have 
    to input the number of signal per wheel revolution to have a correct 

    speed.  

Reviews: