background image

www.heraled.com

2

Safety Information

Warranty

Caution – unplug the power supply from the main power before connecting any cables as this can damage the products.

Caution – avoid looking directly into the led light source at close range for your own safety.

Any people installing this product should comply with local standards and regulations and must be qualified for the handling of

 

electrical equipment

.

•  Do not attempt to install or use the product until installation instructions and safety labels are fully understood. 
    This product is designed for indoor and outdoor usage.
•  Ensure product operates within the specified temperature range. 
•  Do not attempt to open the product.
•  Do not use the product if the power cables are damaged.
•  Only use product for specified voltage.
•  Always maintain connection to ensure waterproofing.
•  If the product has been subjected to drastic temperature variances, for example, following transportation, 
    do not connect the fixture until it has reached room temperature, as moisture condensation may cause electric 
    shock and product damages.
•  When installing the products and system power supplies, please ensure they will not be exposed to moisture and extreme heat 
    (and direct sunlight for outdoor products). Besides, keep a clean operating environment for the fixtures and system power supplies.

.

•  

Any non-compliance of the Installation  Guide  will void the Hera warranty.

Hera warrants    the products for a period of  five (5) years from date of purchase, provided that 
the purchased items are used under the conditions stated in this user manual.

Warning

Please study this Installation Guide throughly and check the latest Technical Specification Sheets available from the 
our website  www.heraled.com before setup.

Marking

DMX

RDM

67

Risk of

Electric

Shock

Do Not Open

Products 

Warning!

Refer to User

Manual. 

 Not Suitable

 for Household Room 

Illumination

 

DIRECTIVE 2012/19/EU 

Waste Electrical 

and Electronic Equipment

 

MPX6 DYNAMIC WHITE SERIES

Summary of Contents for MPX6 DYNAMIC WHITE SERIES

Page 1: ...iced correctly and safely HERA disclaims all liability for damage to the fitting or to other property or persons deriving from installation use and maintenance that have not been carried out in conformity with this instruction manual which must always accompany the fitting HERA reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice V 1...

Page 2: ...e variances for example following transportation do not connect the fixture until it has reached room temperature as moisture condensation may cause electric shock and product damages When installing the products and system power supplies please ensure they will not be exposed to moisture and extreme heat and direct sunlight for outdoor products Besides keep a clean operating environment for the fix...

Page 3: ...uded Working status of fixtures local temperature values voltage input and output serial number and DMX address can be monitored via X PD512 User is informed by mail and system can response automatically according to data Fixtures work compatibly with Madrix software and hardware You can choose fixtures in library in order to have easy pixel mapping MPX 6DW Series are produced in 100 mm 200 mm 300 m...

Page 4: ...Max 40pcs 24VDC 1 5W all LEDs on USITT DMX 512 A Auto Addressing Direct View Color Range White CCT 2700 6500K Diffused View Product Specifications Dimensions H x W x D Ø65x16 mm Ø2 55x0 62 in Ø65x50 mm Ø2 55x1 96 in Weight Viewing Angle 120 180 Pixel Pitch Standart 100mm 200mm 300mm 400mm 500mm up to 1000mm for customized models 0 078 kg 0 17 lb 0 094 kg 0 2 lb Certification PWM Frequency 1 600Hz fli...

Page 5: ... 50 60Hz AC Input 3 Pin VDE The MADRIX Software is the ultimate control tool for LED lighting Use pixel mapping at its best in 2D or 3D PC Ethernet RJ45 RJ45 RJ45 RJ45 RJ45 RISK OF ELECTRIC SHOCK 90 264VAC 50 60Hz RISK OF ELECTRIC SHOCK DMX Signal Maximum Leader Cable length must be 30 meters Maximum in Chain 20 meters or 40 pieces 6 Pole Male XLR Connector 2 Pin Power Connector RJ45 DMX IN DMX OU...

Page 6: ...Instruction Installation Instruction Minimum clearance from dot 20mm 0 79 Warning Do not twist the cable Do not bend the cable Install the product without stretching the cable Make space as 20mm cap 2 0 m m MPX6 DYNAMIC WHITE SERIES ...

Page 7: ... isolating the cable with RTV silicon to protect last product cables after montage 1 Montage with plastic cable tie as shown in the figure 2 With Plastic Cable Tie Assembly 1 Montage without stretching product s cables in case of using plastic cable tie RTV Silicon RTV Silicon P20043 MPX Cable Cap MPX6 DYNAMIC WHITE SERIES ...

Page 8: ...P20050 Steel Rope Mounting Bracked apparatus on mesh implementation by following the steps as shown in the figure With Mesh Installation P20044 MPX Series For Dome Accessories Assembly MPX6 DYNAMIC WHITE SERIES Recommended Steel Rope Thicknees 1 5mm 2 ...

Page 9: ...ts Accessories Accessories Recommended Products P20044 MPX Series For Dome P08015 X PD 512 RDM Addressable Pixel Driver 20050 Steel Rope Mounting Bracked P20040 3 5 Pin Leader Cable for MPX Series 5Meter P20041 3 5 Pin Leader Cable for MPX Series 10Meter P20042 3 5 Pin Leader Cable for MPX Series 20Meter 20043 MPX Cable Cap P08020 Mean Well ELG240 24A 240Watt 24V 8 4A IP67 SMPS P08017 Mean Well EL...

Page 10: ...www heraled com ...

Reviews: