1 - INTRODUCTION                                        

 

 

IMPORTANT!  All  local  regulations,  including  those  that  refer  to  national  or  European 
regulations, must be applied when installing this device.

 

The way the E-30 XS Stove is installed will decisively affect safety issues and its correct operation. 
It  is  important  to  install  the  fireplace  correctly. For  the  correct  installation of  the E-30  Stove 
and chimney, we recommend the installation be 
performed by a professional. 
The E-30 XS Stove provides heat by radiation; directly heating walls, ceilings... 

 

Special care must be taken when installing a stove such that the requirements of the Health & 
Safety at Work Act are met. 

Handling 

 

Adequate facilities must be available for loading, unloading and site handling.  

Fire Cement 

 

Some types of fire cement are caustic and should not be allowed to come into contact with the 
skin. In case of contact wash immediately with plenty of water.  

 
PREPARATORY WORK AND SAFETY CHECKS 
IMPORTANT WARNING 

This stove must not be installed into a chimney that serves any other heating appliance. There 
must not be an extractor fan fitted in the same room as the stove because this can cause the 
stove to emit fumes into the room. 

Asbestos 

This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the coarse of 
installation then please seek specialist guidance and use appropriate protective equipment. 

Metal Parts 

When installing or servicing this stove care should be taken to avoid the possibility of personal 
injury. 

CO Alarms:- 

Building regulations require that when ever a new or replacement fixed solid fuel or wood/biomass 
appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as 
the appliance. Further guidance on the installation of the carbon monoxide alarm is available in 
BS EN 50292:2002 and from the alarm manufacturer’s instructions.

 Provision of an alarm must 

not be considered a substitute for either installing the appliance correctly or ensuring 
regular servicing and maintenance of the appliance and chimney system. 
Stove paint Aerosols 
Paint aerosols are flammable and therefore dangerous to use around a lit stove. Be sure to 
allow aerosols spray paints to dry  and ventilate the room well  before lighting the stove. 
The use of any aerosol around lit stove is dangerous and care must be take in handling 
aerosols. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for E-30 XS

Page 1: ...MULTIFUEL STOVE E 30 XS USE AND MAINTENANCE INSTRUCTIONS Foruse in Great Britainand Republic of Ireland...

Page 2: ......

Page 3: ...or warning Industrias Herg m S A domiciled in Soto de la Marina Cantabria Spain offers a TWO YEAR warranty on its products The geographical coverage of the said warranty only includes the countries in...

Page 4: ...ed in the same room as the stove because this can cause the stove to emit fumes into the room Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the coars...

Page 5: ...ash box behind the door to the fire chamber Grate shaker for use with coal also behind the door Air inlet from the exterior or independent living room through the rear connector at the back of the st...

Page 6: ...that the rear protector panel of your stove has a round cut out piece held in place at three points Push and pull the top of the circle several times gently outwards and inwards The piece will come o...

Page 7: ...ning firewood it is advisable to close it completely once the fire has been lit This valve is normally used for regulating the coal combustion Primary air valve Glass cleaning Open the valve to its fu...

Page 8: ...etroleum derivatives This will render the product warranty void For supplies of adequate coal supplies please contact your stove dealer CONSUMPTION The consumption for the stove according to the tests...

Page 9: ...onvenience control combustion and never overheat the heater INDUSTRIAS HERG M S A may not be held liable for the deterioration of the stove s enamel if these instructions are not followed 6 CLEANING M...

Page 10: ...ial supervision as well as pets away from the fireplace when it is in use Make sure that children or other people who are not familiar with how the device works are supervised by responsible people wh...

Page 11: ...he minimum diameter and the maximum length of the pipe to be connected 8 STROUBLE SHOOTING 1 Fire Will Not Burn check a the air inlet is not obstructed in any way b that chimney and flue ways are clea...

Page 12: ...9 MEASURES...

Page 13: ...meter of outer air inlet connection pipe mm 80 80 Maximum length of outer air inlet connection pipe 1 m 8 8 1 For distances exceeding 8 m consult please In the case of other dimensions consult your De...

Page 14: ...11 EXPLODED VIEW...

Page 15: ...the said repairs may cause POS CODIGO NOMBRE 1 9920201 CONJUNTO MANDO CIERRE PUERTA HOGAR 2 9920560 CONJUNTO PUERTA HOGAR 3 9920197 CONJUNTO BISAGRA PUERTA HOGAR 4 9920561 CONJUNTO CRISTAL 5 9920562...

Page 16: ...DATA PLATE...

Page 17: ......

Page 18: ...NOTES...

Page 19: ......

Page 20: ...INDUSTRIAS HERGOM S A SOTO DE LA MARINA CANTABRIA Apdo de correos 208 SANTANDER Tel 0034 942 587 000 E mail hergom hergom com www hergom com C03602 Versi n 2...