background image

Ash box. Very important!

 

Never open the ash box if the stove is in operation. Always operate the ash box when the 
stove is cold.

 

Access can be had to the ash box by opening the fire chamber door 
To  clean  the  fire  chamber  of  ash,  first  use  the  cold 
handle  to  move  the  shaker  rods  inwards  so  as  to  turn 
the slats of the grate-shaker to the open position. 
Extract the ash box and clean out the ashes  
Once it has been emptied of ashes replace the ash box 
and push it in as far as it will go.  
Again  leave  the  slats  of  the  shaker  in  the  closed 
position, pulling the cold handle outwards.  
Extract the cold handle again. 

 

5 - LIGHTING UP AND USE                            

 

 
RECOMMENDED FUELS 
WOOD 

Use  logs  with  a  humidity  level  lower  than  20%. 
Firewood  should  be  left  to  dry  between  12  and  18 
months to achieve this level of humidity. 
Poor  quality  wood  causes  combustions  of  low  efficiency,  condensations and  reduces  the  self-cleaning  of 
the glass, as well as the life of the stove. 
Do not burn wood from construction sites, painted or treated wood, prefabricated boards or treated pallets. 
 

COAL 

Use only anthracite coal or special prefabricated briquettes for use in heating systems. 
Do not use bituminous or petroleum derivatives. This will render the product warranty void. 
For supplies of adequate coal supplies, please contact your stove dealer. 
 

CONSUMPTION 

The  consumption  for  the  stove  according  to  the  tests  carried  out  pursuant  to  the  EN13240  standard  for 
intermittent use is as follows:  

Beech wood    1,46 Kg./h 
Anthracite 

 0,69 Kg/h  

 

Important at first start: 

may come off a few drops of condensed water from the stove, produced 

by the humidity of the environment where the stove was stored. 
It is very important that the first time the heater is lit, it is done so slowly. 
This is for the following reasons: 
•    Stabilise cast iron parts. 
• 

Harden the joint sealant putty.  

Advise: 
• 

We recommend that the first loads of fuel be small. 

• 

To    generate    draw,    heat    the    chimney    by introducing some burning paper in the gap 

between the front and the deflector,  directing it toward the chimney. 
• 

While lighting for the first time, ensure the room where the heater is located is well ventilated as 

the paint work may let off some fumes. 
• 

Keep  the  stove  on  for  a  few  hours  at  this intensity. 

 

Please note that during use, the seal on the door may loose its colour. This is normal.

 

• 

IMPORTANT!  The  total  height  of  the  fire  load should not  exceed 50% of the height of 

the combustion chamber.

 

• 

The  heater  must  be  closed  at  all  times  during  combustion  to  prevent  smoke  from 

leaking out. Only open to add fuel.

 

 
 
 
 

FIG.7 

Summary of Contents for E-30 XS

Page 1: ...MULTIFUEL STOVE E 30 XS USE AND MAINTENANCE INSTRUCTIONS Foruse in Great Britainand Republic of Ireland...

Page 2: ......

Page 3: ...or warning Industrias Herg m S A domiciled in Soto de la Marina Cantabria Spain offers a TWO YEAR warranty on its products The geographical coverage of the said warranty only includes the countries in...

Page 4: ...ed in the same room as the stove because this can cause the stove to emit fumes into the room Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the coars...

Page 5: ...ash box behind the door to the fire chamber Grate shaker for use with coal also behind the door Air inlet from the exterior or independent living room through the rear connector at the back of the st...

Page 6: ...that the rear protector panel of your stove has a round cut out piece held in place at three points Push and pull the top of the circle several times gently outwards and inwards The piece will come o...

Page 7: ...ning firewood it is advisable to close it completely once the fire has been lit This valve is normally used for regulating the coal combustion Primary air valve Glass cleaning Open the valve to its fu...

Page 8: ...etroleum derivatives This will render the product warranty void For supplies of adequate coal supplies please contact your stove dealer CONSUMPTION The consumption for the stove according to the tests...

Page 9: ...onvenience control combustion and never overheat the heater INDUSTRIAS HERG M S A may not be held liable for the deterioration of the stove s enamel if these instructions are not followed 6 CLEANING M...

Page 10: ...ial supervision as well as pets away from the fireplace when it is in use Make sure that children or other people who are not familiar with how the device works are supervised by responsible people wh...

Page 11: ...he minimum diameter and the maximum length of the pipe to be connected 8 STROUBLE SHOOTING 1 Fire Will Not Burn check a the air inlet is not obstructed in any way b that chimney and flue ways are clea...

Page 12: ...9 MEASURES...

Page 13: ...meter of outer air inlet connection pipe mm 80 80 Maximum length of outer air inlet connection pipe 1 m 8 8 1 For distances exceeding 8 m consult please In the case of other dimensions consult your De...

Page 14: ...11 EXPLODED VIEW...

Page 15: ...the said repairs may cause POS CODIGO NOMBRE 1 9920201 CONJUNTO MANDO CIERRE PUERTA HOGAR 2 9920560 CONJUNTO PUERTA HOGAR 3 9920197 CONJUNTO BISAGRA PUERTA HOGAR 4 9920561 CONJUNTO CRISTAL 5 9920562...

Page 16: ...DATA PLATE...

Page 17: ......

Page 18: ...NOTES...

Page 19: ......

Page 20: ...INDUSTRIAS HERGOM S A SOTO DE LA MARINA CANTABRIA Apdo de correos 208 SANTANDER Tel 0034 942 587 000 E mail hergom hergom com www hergom com C03602 Versi n 2...

Reviews: