TECHNICAL SPECIFICATIONS
•
Maximum input level: Over +22 dBu.
•
Maximum output level: Over +26.5 dBu into 600 ohms.
•
Self-Noise: Less than -75dBu 20Hz-20Khz. -80dBu A-weighted.
•
THD+N (50Hz- 20Khz): not engaged, less than 0.07% at +20dBu.
•
Frequency response, COMPRESS and LIMIT OUT, +- 0.5dB, 15Hz-
30Khz.
•
Input impedance: 10Kohms, transformer balanced and floating.
•
Output impedance: Less than 75 ohms, transformer balanced and
floating, Class A driven.
•
Compressor characteristics: Threshold from –20 to +20 dBu on a 41-
step precision potentiometer. Ratio selectable on a rotary switch,
1.5:1, 2:1, 3:1, 4:1, 6:1. Release selectable on a rotary switch, 100,
400, 800, 1500 mS, A1 and A2 auto release times. A1 corresponds to
50mS on peaks and around 500mS on sustained program. A2 to 50mS
on peaks and 1.5 seconds on sustained program.
•
Limiter characteristics: Limit level selectable from 0 to +20 dBu on a
41-step precision potentiometer. Release selectable on a rotary
switch, 50, 100, 200, 800 mS, A1 and A2 auto release times. A1
corresponds to 50mS on peaks and around 800mS on sustained
program. A2 to 50mS on peaks and 1.5 seconds on sustained
program.