Z
© 2015 Herman Miller, Inc. Zeeland, Michigan. Printed in the U.S.A.
TM
Locale is among the trademarks of Herman Miller, Inc.
Illustrations and specifications are based on the latest product information available at the time of publication.
The right is reserved to make changes in design and specifications at any time, without notice, and also to discontinue products.
Part no. 1bc57y rev B.
9
10
WIRE
POWER BLOCK WIRING DIAGRAMS 4-4-2
4 HOTS, 4 NEUTRALS, 2 GROUNDS
ALLOWABLE CIRCUIT COMBINATIONS: 1,2,3,4 ; 1,2,3 ,4 ; 1, 2 ,3 ,4 ; 1,2,3,4,1 ,2 ,3 ,4
ALLOWABLE CIRCUIT COMBINATIONS: CIRCUITS 1,2, 3, 4 ; 1, 2, 3,4 ; OR 1, 2, 3 ,4