Installation
for the technician
Boiler location
INSTALLATION ROOM
When having an heat ouput lower than 35 kw (about 30000 Kcal/h), particular features for the
installation room are not required. Shortly, all installation rules assuring a safe and regular gas
boiler operation, must be strictly respected.
Place here all necessary
advices according to national rules about:
- Installation room requirements
- Limitations in power and/or number of boilers and other appli-
ances in the same room
Law number XXXX
“Law title and/or brief description”
ROOM VENTILATION (mod.
HABITAT 2 23 E –
natural draught)
When a natural draught boiler is installed, permanent ventilation of the installation
room is mandatory and extremely important. Ventilation must be made and sized in
accordance with Laws and Rules in force.
INSTALLATION IN ROOMS WHERE TEMPERATURE CAN DROP DOWN TO 0°C:
When the installation place does not guarantee an adequate repair against atmospheric agents,
the gas boiler must be completely protected through an adequate coverage as a safety measure
against the above agents.
Thanks to its antifreeze system, inner components could never reach a temperature lower than
5°C. This system is activated when the boiler is supplied by the electrical and gas lines, provided
that the pressure in the heating system is correct.
In case of boiler installation in rooms where temperature can drop down to 0°, it is advisable to
protect the heating circuit with an antifreeze liquid.
See also “System filling” and “Boiler inactivity”
.
This appliance is not suitable for outdoor installation.