background image

 

 

Additional option: automatic activating 
The device can be set up by an expert in such a way, that it switches itself by 
unlocked door at the end of a time automatically again active. The time can be 
set up from one minute up to 8 minutes. 
Version: Activate the door with the key, i.e. inactive (1 left-hand rotation

 

i.e. 1 

anti-clockwise rotation) . 
Should you forget to switch the door again ready to alarm, now this happens 
automatically and without your assistance. Of course the device can also be  
switched active during this time by hand with the key. Attention: The automatic 
activating occurs without consideration whether the door was closed again 
(alarm!). Nevertheless, before (change-over unlocking  -> active) an acoustic 
signal sounds 10 times every second. 
 
Additional option: automatic activate delaying with inevitability 
The device can be set up by an expert in such a way, that it delays the manual 
activating >10 seconds

Version: Activate the door with the key in alert (1 right-hand rotation

 

i.e. 1 

clockwise rotation). Now an acoustic signal sounds every second (Change-over 
unlocking  -> active). You have approx. 10-second to open the door without 
causing an alarm.  
As long as the door is open, the time clock stops. The device switches 
only after closing the door and after the expiration

 

of full 10 seconds 

again active (inevitability). 
With this setting you can use, e.g., as an authorised person, the emergency exit 
to leave the space without causing an alarm  and you can allow somebody to 
switch the door afterwards again automatically ready to alarm. Or you can use 
the emergency exit as long as you let the door open. Pay attention always to 
close the door after use ! 

 

Additional option: External lock 
Switching the device by authorized persons with key can also be carried out by 
an external lock. Notice that all additional locks have equal rights. So avoid 
preferably mixed using

 

and inform yourself about the operating status of the 

yellow LED before switching so that you don`t cause failure accidentally.

 

 

Setting notes: 

(To fill out from the expert: please stroke non-appropriate) 

automatic activate delaying activated: 

 

 

N 

automatic activating activated :   

 

 

N 

 

    - if yes, please note time: 

 

 

______ minutes 

The bold printed letters marked the factory setting. 

  