10.4.12 I
– Adjust RF module
It is necessary to adjust the RF module in order to adapt an antenna to t he ambient conditions
optimally.
The tuning achieves an optimal read / write range for the present installation environment
.
Tuning is performed one at a time for the antenna port and the determined tuning value is stored for the
antenna.
For optimal results, the vote should be automatic, but the voting value can also be set manually.
Host
Device
CMD
Reader-ID
Vote value
I
1 Byte
2 Bytes
Device
Host
CMD
Reader-ID
i
1 Byte
To start the auto-tuning process, select the value 10
.
Example:
I110
…
automatic tuning of antenna 1
If the reader can not determine the appropriate calibration
, the error "5 - Invalid" is sent instead of the