Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader
15.01.2019
Page 58 of 119
HERMOS AG
Gartenstrasse 19
Tel. +49(9279) 991-0
D-95490 Mistelgau
Fax. +49(9279) 991-100
10.4.17 Q
–
Querying the status of the inputs and outputs
The Q command can be used to query the current status of all outputs
. The status of the outputs is
queried in a message.
In the current version, the value of the data element Head-ID always has the
value "1" for the outputs.
Host
Device
CMD
Reader-ID
Head-ID
Q
1 Byte
1 Byte
Device
Host
CMD
Reader-ID
Head-ID
Output
Index
Output
State
LED1
…
Output
State
LEDA
q
1 Byte
1 Byte
1 Byte
1 Byte
…
1 Byte
Example: Status LEDs
>> Q01
<< q012000000001 external LED (2 = flash), green status LED (1 = on)
The status of the input sensor can be queried via head ID „0“.
In this case, the answer contains the sensor state (0-1) instead of the 10 output states.
Example: Status of input sensor
>> Q00
<< q000