Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader
15.01.2019
Page 85 of 119
HERMOS AG
Gartenstrasse 19
Tel. +49(9279) 991-0
D-95490 Mistelgau
Fax. +49(9279) 991-100
Protocol commands
The message record describes the communication data between a reading device with and a host. The
following functions can be used via commands by the host in the reading device or automatically
transmitted from the reading device to the host:
Stream 1: (System state)
Are you there request
S1F1
(Host
Reader)
Request Offline
S1F15
(Host
Reader)
Request Online
S1F17
(Host
Reader
Stream 2: (System control)
Read parameter
S2F13
(Host
Reader)
Write parameter
S2F15
(Host
Reader)
Transmit reset
S2F19
(Host
Reader)
Stream 3: (Material state)
MID detected by sensor
S3F5
(Reader
Host)
MID removed from sensor
S3F7
(Reader
Host)
Read MID
S3F13
(Reader
Host)
Stream 5: (Exception handling)
Alarm message
S5F1
(Reader
Host)
Stream 9: (System error)
Unrecognised device ID
S9F1
(Reader
Host)
Unrecognised stream type
S9F3
(Reader
Host)
Unrecognised function type
S9F5
(Reader
Host)
Invalid data
S9F7
(Reader
Host)
Transmission timeout
S9F9
(Reader
Host)
Stream 18: (System state)
Read parameter
S18F1
(Host
Reader)
Write parameter
S18F3
(Host
Reader)
Read data
S18F5
(Host
Reader)
Write data
S18F7
(Host
Reader)
Read MID
S18F9
(Host
Reader)
Write MID
S18F11
(Host
Reader)
Subsystem command
S18F13