Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader
15.01.2019
Page 106 of 119
HERMOS AG
Gartenstrasse 19
Tel. +49(9279) 991-0
D-95490 Mistelgau
Fax. +49(9279) 991-100
49
0x31
B-Message
Support of B-Message at ASC-I1 Protocol
0 … deaktivate B-message
1
… aktivate B-message
Default :
54
0x36
SWITCHTUNEON
Duration how long the push button key TUNING
must be pressed until it changes to the state
"On".
1 ... 100 (100 ms)
Default :
1 (100ms)
55
0x37
SWITCHTUNEOFF
Duration how long the push button key TUNING
must be pressed until it changes to the state
"OFF".
1 ... 100 (100 ms)
Default :
1 (100ms)
56
0x38
SWITCHTESTON
Duration how long the push button key TEST has
to be pressed until it changes to the state "ON".
1 ... 100 (100 ms)
Default :
30 (3s)
57
0x39
SWITCHTESTOFF
Duration how long the push button key TEST has
to be pressed until it changes to the state "OFF".
1 ... 100 (100 ms)
Default :
1 (100ms)
58
0x3A
Push Button switch status
(read only)
The parameter is used to query the state of the
push button switches
Bit0: TUNING (0=OFF, 1=ON)
Bit1: TEST (0=OFF, 1=ON)
59
0x3B
Hardware error detection
(read only)
The read-only parameter returns the complete
identifier of the current firmware
.
0 … no hardware error
1 … detect antenna adjustment error
2 … detect antenna volatage error
66
0x42
Antenna adjustment
(read only)
The read-only parameter returns the antenna
adjustment if there is no hardware error.
255 … on hardware error
00 … 15 adjustment
67
0x43
antenna powerage for all
adjust steps
(read only)
The read-only parameter returns the antenna
power at a defined adjustment step of the the
adjustment procedure. Only available if a
automatic antenna adjustment was running
before. The fist byte shows the adjustment step
(00 … 0F) the next two bytes shows the antenna
powerage to this step.