Now blow the dust from the surface of the
paper element about 50 mm away from
O
it, with the air nozzle at an angle of 45
and moving it along the paper pleats.
9
11
(9) Air cleaner element (10) Element holder
(11) Air nozzle
10
O
45
50 mm
î
Replace it earlier if it becomes very dirty,
damaged on surface or on the sealing area.
Install the air cleaner element on holder,
insert the air cleaner assembly into the inlet
air duct & press gently to fix the mounting
clamp in housing. Ensure cover lug should
CAUTION
!
!
î
Never blow air initially from outside to
inside as the fine dust particles may go deep
inside the element.
î
Never wash the air cleaner element. Only blow
air for cleaning the dust, as explained. Replace
air cleaner element every 12000 km.
AIR CLEANER DRAIN TUBE
Drain the deposit into a suitable container by
pressing the drain tube end. Follow the above
process more frequently when riding in rain or
at full throttle.
(1) Drain tube
1
Check for smooth rotation of the throttle grip
from the fully open to the fully closed position.
Check at full left and full right steering
positions. Inspect the condition of the throttle
cable from the throttle grip down to the
THROTTLE OPERATION
Cable Inspection
32
take proper seat on the other side of the
mounting clamp.
Summary of Contents for HF-Deluxe