background image

 

 

 

#HeroCamper™ – Lammefjordsvej 5 – 6715 Esbjerg N – Denmark 

Phone +45 7022 5840 

– sales@herocamper.com 

www.herocamper.com 

VAT No DK -40193189 

 

Safety instructions 

WARNING! 

• Do not operate the appliance if it is visibly damaged.

 

• Do not block the 

gaps of the fridge with things like pin, wire, etc.  

• Do not expose the appliance to rain or soak it in water.

 

• Do not place the appliance near naked flames or other heat sources (heaters, direct sunlight, gas 

ovens etc.) 

• Do not store any explosive sub

stances like spray cans with a flammable propellant. 

• Ensure the supply cord is dry and not trapped or damaged. Do not locate multiple portable socket

-

outlets or portable power supplies at the rear of the appliance.  

• Check the voltage specification on t

he type of plate corresponds to that of the energy supply. The 

appliance is only to be used with the power supply unit provided with the appliance. 

• Do not use 

electrical appliances inside the food storage compartments of the appliance, unless 

they are of the type recommended by the manufacturer. 

• Once unpacked and before turning on, the appliance must be placed on a level surface for more 

than 6 hours.  

• Make 

sure that the appliance stays horizontally when it is running. The tilt angle must be less than 

5° for long time running and be less than 45° for brief time running. 

• Keep the ventilation openings in the unit casing or in the built

-in structure free of obstacles. 

• Keep the appliance stable on the ground or in the car; Do not drain upside down. 

 

 

CAUTION! 

• Repairs may only be 

conducted by qualified personnel. Incorrect repair may cause danger. The 

lamp and supply cord must be replaced by the manufacturer or qualified persons. 

• The installation of DC power in the boat must be 

managed by qualified electricians. 

• The appliance can only use our dedicated rechargeable batteries, non

-rechargeable batteries are 

prohibited, otherwise there may be a danger of fire and explosion. 

Summary of Contents for CS0504

Page 1: ...Model KTW75 Cooling Box USER MANUAL Please read this operating manual carefully before starting the device Keep it in a safe place for future reference...

Page 2: ...Phone 45 7022 5840 sales herocamper com www herocamper com VAT No DK 40193189 Content Safety instructions 2 Product features 4 Product structure 4 Function and operation 5 Care and maintenance 9 Trou...

Page 3: ...ided with the appliance Do not use electrical appliances inside the food storage compartments of the appliance unless they are of the type recommended by the manufacturer Once unpacked and before turn...

Page 4: ...circuit Risk of child entrapment Before you throw away your old refrigerator or freezer take off the doors leave the shelves in place so that children may not easily climb inside Check if the cooling...

Page 5: ...t insulation Lowest cooling to 20 C 4 F based on 25 C 77 F room temperature Intelligent battery protection system prevents your vehicle from running out of battery LED display control panel for temper...

Page 6: ...e compressor is Power supply connect to DC 12V 24V or AC 100 240V using dedicated adapter or solar 12 50V power supply Display Screen Initialization when the fridge is powered on the buzzer will make...

Page 7: ...ctory setting is MAX Battery Protection Mode under the running state long press for three seconds until screen flashes then press again to select protection mode H High M Medium and L Low Factory sett...

Page 8: ...ress the power button on the battery to switch ON OFF When the battery is OFF short press the power button to show current battery Model FSAK 002 Capacity 15600mAh 173Wh Rated Voltage 11 1V Charging L...

Page 9: ...y power the compressor when the refrigerator is running When connect to a solar panel please place the refrigerator in a cool place to dissipate heat The charging input power should be higher than the...

Page 10: ...ce Storage If the device will not be in use for a long time please follow the instruction Switch off and unplug the device Take out all the items stored in the device Wipe off excess water with a soft...

Page 11: ...on Check if the plug and socket are connected well Check if the fuse has been burnt Check if the power supply is malfunctioned Switch on off the fridge frequently may cause start delay of the compres...

Page 12: ...High to Medium or from Medium to Low Code F2 displayed Possible cause condenser fan is overloaded Disconnect power to fridge for 5 minutes re start If the code shows again contact manufacturer for se...

Page 13: ...er for service For models with FSAK 002 detachable battery if code F1 displayed unplug or turn off the battery or connect to DC12 24V AC100 240V using the adapter power supply to power the compressor...

Page 14: ...mark Phone 45 7022 5840 sales herocamper com www herocamper com VAT No DK 40193189 Technical information Due to product improvement the technical information might be different from actual information...