12
#HeroCamper™ – Lammefjordsvej 5 – 6715 Esbjerg N – Denmark
Phone +45 7022 5840
– sales@herocamper.com
www.herocamper.com
VAT No DK -40193189
Installation (continued)
•
Match the corresponding active
(brown), neutral (blue) and ground
wire (yellow-green) and tighten up
screws to make sure power is
properly connected.
•
Insert plenum mounting bracket
through
the
ceiling
to
base. Pay attention as the “C” hook
must match the
corresponding “C”
area on the base. Finally fasten.
•
Insert 4xM8 bolts, washers, spring
washer and metal plate via
mounting frame to the base.
•
Tie the room temperature sensor
onto the rib of mounting bracket.
•
Plug the connectors on the plenum
to the base.
Push plenum into outlet duct and
fasten 4xM4 screw on the bottom.
Finally add the filters to the sides of
the plenum.
Important: ensure the tightening
torque from 12 to 14 N.m