35
EN
Setting of rotational speed is only possible within the permitted limits.
The transfer of the values occurs only after the button has been activated.
.....
If no error has been registered under the
respective error number in the error history
a dash will be displayed for a short period
of time and then returned.
If a parameter or its limits are not
supported by the firing unit a dash
will be briefly displayed and
then returned.
Parameter
(”Cold adjustment”)
Error History
If an external heat request
signal exists dashes are
briefly displayed and then
returned.
Explanations
- Press the button 3s permanently to change the menu.
- Both points of the 7-segment displays are permanently blinking within the menu structure.
- A return to the previous menu level (turnaround menu) always occurs through Escape (EC).
- A rotary encoder (grey actuated line) enables the selection within a menu level (turnaround menu).
Exception: the turnaround menu is deactivated by adjustment of the blower speed. The respective maximum/minimum
value will also remain with further turning.
- Continous black line shows the direction of movement between the menu levels. A jump forward or back along this line
is actuated by pressing the button.
- Automatic transmission into the next menu level (black spotted line) e.g. after reaching the rotation speed.
- An eBus protocol will be sent only upon activation of the button (read-out or entering of values), i.e. no “Online adjustment”.
- After the request of a value (e.g. P1) the display will extinguish for a short period of time until the read-out value
has been shown. Thereafter the points will continue to blink. If the eBus protocol is faulty the selection (e.g. P1) will be
displayed again.
- Please bear in mind that a maximum of 10 error values can be displayed.
- The non-activation of the button and rotary encoder will cause a “Time-out” after 3 minutes, where by a return to the operating
display (display of operating state) will be released.
The P
menu is only
available if no external request
for a heat
signal exists.
A heat
request is suppressed
within the
P menu