background image

7

Mounting behind a wall using discharge
extension (707U only)

1.  Locate the inside wall template and mount on

inside wall. The inside wall opening must be cut
first. Be sure to follow the limitations noted as A,
B, and C printed on the template.

2.

Check the template with a level to ensure proper
installation of the humidifier.

3.

Drill (6) 5/16” diameter holes through the inside
wall only as shown on the template for mounting
the wire bracket on the wall using the anchor bolts
and flat washers provided. Drill a saw access hole
through the inside wall only in Area I as shown on
the template.

4.  Cut out Area I of the inside wall using a saber saw

or equivalent. Do NOT cut out Area II at this time.
Do NOT cut through the entire wall as the
discharge hole on the other side of the wall will be
higher up. 

5.  Measure the thickness of the wall studs using the

cutout portion (Area I) on the template. This
measurement is used to drill a pilot hole for
locating the hole in the outside wall. 

6.  Drill (1) 1/4” pilot hole through the inside and

outside wall at the proper point in Area II on the
template. This will mark the proper center for the
discharge hole on the outside of the wall.

7. 

Cut out Area II of the inside wall using a saber saw
or equivalent. Do NOT cut through the entire wall.

8.  Remove the template from the wall. In the (6)

5/16” diameter holes previously drilled into the
inside wall, install the (6) anchor bolts provided.
Remove each one of the bolts,  and mount the wire
mounting bracket to the wall with (6) removed
bolts and flat washers. 

9.  The float and valve assembly have been factory

adjusted to maintain 1-1 1/2” of water in the water
reservoir pan at normal water pressure. If
necessary, bend the float arm to the required
position to maintain the water level at other water
pressures.

10.  When installing the atomizing assembly into the

water reservoir pan, be sure that the drip tubes do
not interfere with the operation of the float and
valve assembly. Interference can be eliminated by
rotating the entire atomizing assembly within the
water reservoir pan.

Physical installation

NOTE:

The following items are located in
the carton:

• Bottom pan

• Extension discharge 

nozzle

• Atomizing assembly

• Discharge dome (plastic) 

• Wire mounting bracket 

The following items are located in
the bag identified :

“707 TW Hardware Kit”:

• Inside wall template

• Outside wall template

• (6) anchor bolts

• (1) flexible connector sleeve 

• (2) hose clamps

• (1) bezel 

The following items are located in
the bag identified :

“707 SM/STD Hardware Kit”:

• (6) #10 flat washers

Inside wall

Wire mounting bracket

Bracket should be level

Summary of Contents for 707U

Page 1: ...11 Maintenance 12 Unit Diagram and Parts List 14 Warranty Back cover Manual for Installation Operation Maintenance Duct Mount Centrifugal Atomizer Humidifier Table of Contents 256703 001 7 04 CAUTION...

Page 2: ...into the home and heated When heated this air dries out and greatly increases its capacity to hold more moisture By using a humidifier a source of water is provided to satisfy this increased moisture...

Page 3: ...turn the humidistat to the OFF position Sq Footage of Home 1000 1500 2000 2500 3000 4000 Tight Home GPD 0 5 3 0 5 0 7 5 10 0 14 5 Average Home GPD 5 0 10 0 14 0 19 0 23 5 33 0 Loose Home GPD 10 0 16...

Page 4: ...at least six 6 linear feet preferably 10 feet upstream from any electronic air cleaner Failure to follow this recommendation can cause excessive nuisance arcing and or power supply failure If the duct...

Page 5: ...rge nozzle should be at least two 2 feet below the ceiling and from a vertical wall along the side The discharge nozzle should be about six and a half 6 1 2 feet from the floor If this is not possible...

Page 6: ...cturer s original warranty Remember to select a location that is readily accessible for periodic inspection and cleaning of your humidifier Allow a minimum of 2 clearance in front of the humidifier an...

Page 7: ...position with 2 10 sheet metal screws and flat washers provided 10 The float and valve assembly have been factory adjusted to maintain 1 1 1 2 of water in the water reservoir pan at normal water pres...

Page 8: ...II of the inside wall using a saber saw or equivalent Do NOT cut through the entire wall 8 Remove the template from the wall In the 6 5 16 diameter holes previously drilled into the inside wall insta...

Page 9: ...sion nozzle provided will be 2 5 8 long PLUS the total wall thickness as determined in the previous step Cut the extension nozzle to length on the square end The opposite end of the extension nozzle i...

Page 10: ...copper tubing to the float and valve assembly with the ferrule and compression nut provided Caution The float and valve assembly must not turn when tightening the copper tubing compression fittings to...

Page 11: ...operation of the humidifier during the heating season 3 The humidifier will only operate when the furnace blower is in operation 4 It is recommended to install a humidistat provided with model 707U i...

Page 12: ...hrow switch may be installed 4 Turn the humidistat to the highest level past 60 and the humidifier should begin to run The humidifier should stop when the humidistat is turned off 5 Set the furnace co...

Page 13: ...ly therefore the frequency of cleaning the unit also varies During the heating season check for film or scale build up in the unit or any moving part Establish a proper cleaning schedule to ensure the...

Page 14: ...Remove the pump from the end of the impeller shaft If the pump is stuck in the motor drive shaft run hot water over the end of the shaft for a few seconds to loosen the pump 8 Flush water through the...

Page 15: ...SCREEN 6 1 1 D9P IMPELLER 7 1 1 M3 SCREW SET CUP 8 1 1 8A IMPELLER PUMP 9 4 4 90 VIBRATION DAMPER 10 1 1 35P CENTER PAN 11 4 4 23 CENTER PAN SUPPORT 12 2 2 27 DRIP TUBE 13 1 1 92P FLOAT VALVE ASM 14...

Page 16: ...ders com Humidifiers which have been installed or become part of real estate cannot be returned CareCo will receive freight prepaid only removable parts or components of such defective humidifiers 6 T...

Reviews: