background image

14

Warranty

Humidifier Limited Two Year Warranty

This limited warranty covers Herrmidifier Residential Type Humidifiers, excluding duct work, wiring and
installation. The manufacturer warrants that all new Herrmidifier Humidifiers are free from defects in material
and workmanship under normal, non-commercial use and service. The manufacturer will remedy any covered
defects if they appear within 24 months from the date of original installation as evidenced by proof of
purchase, subject to the terms and conditions of this Limited Two-Year Warranty stated below:

1.

THIS LIMITED TWO-YEAR WARRANTY is granted by CareCo, 415 W. Wabash Ave., P.O. Box 200,
Effingham, IL 62401.

2.

This warranty shall extend only to any non-commercial owner who has purchased the residential
humidifier other than for purposes of resale.

3.  All components are covered by this limited warranty except expendable items, such as evaporative pads,

media filter pads and nozzles.

4.

If, within the warranty period, any Herrmidifier residential humidifier unit or component requires
service, it must be performed by a competent heating and/or air conditioning contractor (preferably the
installing contractor). CareCo will not pay shipping charges or labor charges to remove or replace such
defective parts or components. If the part or component is found by inspection to contain such defective
material and workmanship it will be either repaired or exchanged free of charge at CareCo's option,
and returned freight collect.

5.

In order to obtain the benefits of this limited two-year warranty, the owner must notify the dealer or
distributor of any defect within 30 days of its discovery. If after reasonable time you have not received
an adequate response from the dealer or distributor, notify in writing 

CareCo Service Dept., 415

Wabash Ave., P.O. Box 200, Effingham, Illinois, 62401, or call 1-866-829-2440 or email 
fiaqcustomerservice@fedders.com

. Humidifiers which have been installed or become part of real

estate cannot be returned. CareCo will receive, freight prepaid, only removable parts or components of
such defective humidifiers.

6.

This limited warranty does not apply to any part or component that is damaged in transit or in handling,
has been subject to misuse, neglect or accident; has not been installed, operated and serviced according
to Herrmidifier's instructions; has been operated beyond the factory rated capacity; or altered in any
such way that its performance is affected. There is no warranty due to neglect, alteration or ordinary
wear and tear. Herrmidifier's liability is limited to replacement of defective parts or components and
does not include the payment of the cost of labor charges to remove or replace such defective
components or parts.

7.

CareCo will not be responsible for loss of use of any product; loss of time, inconvenience, or any other
indirect, incidental or consequential damages with respect to person or property, whether as a result of
breach of warranty, neglect or otherwise. SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE LIMITATION OR EXCLUSION IN THE
PRECEDING SENTENCE MAY NOT APPLY TO YOU.

8.

THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY
FROM STATE TO STATE.

9.  Any warranty by CareCo of merchantability, fitness for use or any other warranty (express, implied or

statutory), representation or guarantee other than those set forth herein, shall expire at the expiration
date of this express limited warranty. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN
IMPLIED WARRANTY LASTS, SO THE LIMITATION IN THE PRECEDING SENTENCE MAY NOT APPLY TO
YOU.

10. Herrmidifier reserves the right to make changes in the design and material of its products without

incurring any obligation to incorporate such changes in units completed on the effective date of such
change.

CareCo Service Dept., 

415 Wabash Ave., P.O. Box 200, Effingham, Illinois, 62401 

Phone: 1-866-829-2440

E-mail: fiaqcustomerservice@fedders.com

Summary of Contents for G-200/300

Page 1: ...t Bypass Humidifier Installation Operation Maintenance CAUTION READ INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS CAREFULLY FOR SAFE OPERATION EXERCISE EXTREME CAUTION WHEN WORKING WITH ELECTRIC...

Page 2: ...tents Introduction 1 Specifications 2 Capacity Selection Guide 3 Operation 3 Installation 5 Mounting Locations 6 Maintenance 7 Troubleshooting 9 Description of Parts 11 Unit Diagram and Parts List 12...

Page 3: ...at 71 to 72 F without controlled humidity Since every degree of temperature setback represents about 3 of your heating costs this can possibly represent a significant annual savings During the heatin...

Page 4: ...idifier as part of the summer shut down Be sure to install a new evaporator pad at the beginning of the heating season before starting the humidifier Like your heating system and air conditioning unit...

Page 5: ...water by using the saddle valve It is designed to be either fully open or closed A pad in the distribution tray distributes water evenly between the openings The distribution tray should be inspected...

Page 6: ...ols and humidistat for the desired conditions 30 40 Relative Humidity is typically recommended but it is important to reduce the setting whenever extreme low outdoor temperatures occur in order to avo...

Page 7: ...urnaces using 120VAC auxiliary terminals interlocked to the furnace fan connect the primary of the supplied 120 24VAC transformer to the auxiliary terminals on the furnace Connect the secondary of the...

Page 8: ...recommended that when the unit is installed in this location it is supplied with hot water service 2 If the furnace has an air conditioning coil be sure the unit does not interfere with coil ends 3 R...

Page 9: ...d be installed upstream of the conical mesh filter to reduce the frequency of cleaning Water softeners can be used to improve the quality of the supply water however deionized water is corrosive and c...

Page 10: ...drain connection Remove the old evaporator pad and discard 5 Inspect the interior of the humidifier and remove any mineral deposits and accumulation from the frame assembly and drain tray 6 Remove th...

Page 11: ...ould be an improper electrical installation The humidifier is designed to be used in conjunction with the furnace blower Q Water is constantly flowing out the humidifier drain and I am afraid that it...

Page 12: ...Corrective Action Replace the evaporator pad Clean or replace conical mesh filter and fluid restrictor Increase the humidity setting on the humidistat Turn the saddle valve handle in a counterclockwi...

Page 13: ...vaporator Pad Allows water to evaporate as warm dry air is drawn through it Must be replaced on a regular basis to maintain efficiency Fluid Restrictor Located within the water tubing of the humidifie...

Page 14: ...001 454278 002 G 109 G 125 12 353226 002 G 206 6 G 217 12 G 123 454281 002 454280 002 G 139 454279 002 G 105 IN 2ST 352680 004 351454 015 454278 002 G 109 G 125 12 353226 002 G 206 6 G 217 12 G 123 4...

Page 15: ...13 Unit Diagram 1 2 3 4 5 6 8 9 10 12 14 13 11 7...

Page 16: ...edders com Humidifiers which have been installed or become part of real estate cannot be returned CareCo will receive freight prepaid only removable parts or components of such defective humidifiers 6...

Reviews: