The mounting position of the unit must ensure that any mechanical damage to the flexible cable is unlikely.
Excess cable should be secured and must not touch hot parts of the heater and should not encroach into
the heated area. Do not allow the cable to act as a conduit for water into the cable gland on the back of the
heater.
Colour coding used in the supplied mains cable:
BROWN wire is to be connected to LIVE (‘L’), the BLUE wire to NEUTRAL (‘N’) and the GREEN/YELLOW wire
to EARTH (‘E’).
MOUNTING POSITION:
The Herschel HAWAII is a middlewave infrared heater suitable for use in cold indoor or semi-sheltered
outdoor areas. When used outdoors or other areas with air movement/wind, the directional Infrared spread
may reduce by 1/3 to 1/2 from published figures.
The HAWAII must be suspended using the chain kit provided from a firm structure forming part of an
overhead shelter. The heater must not be exposed to rain or water ingress from above.
The sides and ends of the heater must always be at least 300mm (12”) away from the nearest wall, ceiling
or other structure. The unit must be suspended using the chain (supplied). You can wrap the chain around
a fixture and clip it back to itself using the buckle clip provided so long as the heater can hang 300mm from
the ceiling.
For all installations, the HAWAII must be located in a position to allow proper and efficient use but one that
ensures hot parts are not touched accidentally. The minimum installation height of the HAWAII above the
floor is 1.8m (71”). Under no circumstances is the unit to be installed at less than 1.8m (71”) from the floor.
Consideration should be given to any temporary or occasional structures such as stages or platforms and
adjusted accordingly.