8
Terms and definitions
46
Betriebsanleitung_firematic_20-301_Touch_Englisch V1.2
Term
Display- / set value
Description
Buffer loading pump
Display value
Indication of the state of the buffer load pump (if
active
indicator lamp will light up green)
Fastrun open
Display value
Indication of the state of rapid heating (if active
indicator lamp will light up green and rapid
heating will be open)
Fastrun close
Display value
Indication of the state of rapid heating (if active
indicator lamp will light up green and rapid
heating will be closed)
8.3
Hot water tank value
Term
Display- / set value
Description
Hot water tank temperature
Display value
Hot water temperature display in °C
Hot water tank pump
Display value
Indication of the state of the hot water tank pump
(current state is stored)
Must temperature
Setting value
Desired target value of the hot water tank
Min. loading / temperature
Setting value
Loading will take place below this value (if
activated)
Temp. increase
Setting value
Required temperature setting. Increase required
due to reduced efficiency. You can enter an
amount to be added to the target temperature of
the storage tank circuit here.
Max. loading time
Setting value
Maximum time for loading the hot water tank
Legio temperatura
Setting value
Hot water tank temperature setting (the water
heater will be heated to this temperature in order
to kill bacteria)
Circulation pump
Display value
Activation of the circulation pump
Loading valve
Display value
Indicator lamp
8.4
Heating circuit
Term
Display- / set value
Description
Flow temperature
Display value
Flow temperature display in °C
Back flow temperature
Display value
Back flow temperature display in °C
Outside temperature
Display value
Outside temperature display in °C
Switching temperature
Display value
Switching temperature setting above which the
change-over
between
summer
and
winter
operation will take place.
Heating circuit mixer
Display value
Indication of the state of the HC mixer (current
state is stored)
Heating circuit pump
Display value
Indication of the state of the HC pump (current
state is stored)
Heating circuit
Setting value
Here you can switch on/off the heating circuit
Operation Mode
Setting value
Here you have the following operating modes to
choose from.
•
Heating time mode
•
Heating corresponds to the set heating time.
•
Continuous heating
•
Always heat to the target room temperature
or to the calculated feed flow target temp.
•
Continuous lowering
•
Always heat to the reduced target room
temperature or to the calculated feed flow
target temperature during the lowering time.