Fault reports and their corrections
10
65
No. Fault report
Cause of fault
Fault correction
001
BOILER SENSOR
Failure boiler temperature sensor
▪
Check sensor, replace as renew
▪
Check plug, replace as renew
▪
Check wiring incl. connections,
replace as renew
▪
✆
- contracting party
002
COMBUSTION ROOM
SENSOR
Sensor break; Value outside the
measuring range
(0 - 1200°C)
Check sensor, replace as renew
Check plug, replace as renew
Check wiring incl. connections,
replace as renew
✆
- contracting party
003
FLUE GAS SENSOR
Sensor break; Value outside the
measuring range
(-10 - 600°C)
Check sensor, replace as renew
Check plug, replace as renew
Check wiring incl. connections,
replace as renew
✆
- contracting party
004
BACK FLOW SENSOR
Sensor break; Value outside the
measuring range
(-10 - 120°C)
Check sensor, replace as renew
Check plug, replace as renew
Check wiring incl. connections,
replace as renew
✆
- contracting party
005
STOKER SENSOR
Sensor break; Value outside the
measuring range
(-10 - 300°C)
Check sensor, replace as renew
Check plug, replace as renew
Check wiring incl. connections,
replace as renew
✆
- contracting party
006
BURNING ROOM MAX
Combustion chamber temperature
over adjusted combustion chamber
temperature max.
adjust Combustion settings
✆
- contracting party
007
BUFFER SENSOR TOP
Sensor break; Value outside the
measuring range
(-10 - 120°C)
Check sensor, replace as renew
Check plug, replace as renew
Check wiring incl. connections,
replace as renew
✆
- contracting party
008
BUFFER SENSOR
BOTTOM
Sensor break; Value outside the
measuring range
(-10 - 120°C)
Check sensor, replace as renew
Check plug, replace as renew
Check wiring incl. connections,
replace as renew
✆
- contracting party
009
WEATHER COMP.
POWER MAX.
Sensor break; Value outside the
measuring range
(-10 - 120°C)
Check sensor, replace as renew
Check plug, replace as renew
Check wiring incl. connections,
replace as renew
✆
- contracting party
010
BUFFER SENSOR
MIDDLE
Sensor break; Value outside the
measuring range
(-10 - 120°C)
Check sensor, replace as renew
Check plug, replace as renew
Check wiring incl. connections,
replace as renew
✆
- contracting party
Summary of Contents for firematic CONDENSATION 30
Page 1: ...OPERATING INSTRUCTIONS Wood chips pellets heating system firematic CONDENSATION 30 40 ...
Page 83: ...Annex 15 83 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 84: ...15 Annex 84 Hydraulic recommendation 2 ...
Page 85: ...Annex 15 85 15 2 Solar module Program 1 ...
Page 86: ...15 Annex 86 Program 2 ...
Page 87: ...Annex 15 87 Program 3 ...
Page 88: ...15 Annex 88 Program 4 ...
Page 89: ...Annex 15 89 Program 5 ...
Page 90: ...15 Annex 90 Program 6 ...
Page 91: ...Notes 16 91 16 NOTES ...