Maintenance schedule
11
75
Item
Procedure
Combustion
chamber tipping
grate
Check burning chamber stones and walls
visually for damages and wear and
conduct cleaning with scraper and broom
(2), afterwards remove ash off burning
chamber. Check and clean burning
chamber vents (3).
Check ignition pipe, if necessary cleaning
Check pivoting grate (4) visually for
damages and wear
Conduct function test of pivoting grate
using the aggregate test
Ash container
Demount ash container cover and check
ash level and empty ash container if
necessary.
Control -
functioning
Check display, operation and faults list
(see chapter fault reports)
Restart T-Control
Control - faults
Opening the front door or ash door of the
boiler
4
2
3