9
T-CONTROL
22
9.4
Symbols explanation
In this section important symbols are explained.
This symbol shows that remote access is currently taking place.
This symbol shows that an e-mail is currently being sent.
This symbol shows that a USB stick is currently connected.
The
CHIMNEY SWEEPING FUNCTION
provides a test mode for the chimney sweeper. The
boiler is operated steadily at nominal output and all consumer values are set to its maximum
during the chimney sweeper carries out its measurements. This condition is left when
deactivation occurs or when the boiler maximum temperature is exceeded or when the
maximum chimney sweeping time is exceeded. All loads are set to the permissible
maximum value. Any measurement may only take place when the display shows "
Chimney
sweep funct..
“ and a corresponding flame has formed. Otherwise there is no guarantee
that the boiler will demonstrate optimum combustion. It is possible that the boiler will only
work in ignition or burning phase. The chimney sweeping time is set to 25 min. , whereby
the remaining time only starts to run when the boiler status chimney sweeping function
begins (ignition phase does not count towards this).
After pressing the chimney sweeping symbol, the boiler can also be switched off in addition
to the nominal output program.
With the
aggregate-test
connected components can be tested individually. The symbol is
only visible, if
•
the code has been entered
•
the boiler is in the “heating off” operation mode (only at the boiler aggregate-test!)
When the aggregate test is active, the symbol turns green. Then the aggregates can be
activated.
Information
such as firmware-module, hardware-module, software version etc., of each
module (boiler, hot water tank, buffer, solar, heating circuit).
These symbols (
navigation
) can be used to navigate in each module (boiler, hot water tank,
buffer, solar, heating circuit, hydr. compensator, net pump, zone valve, ext. demand). An
alternative to the illustrated navigation method is the wiping up or down.
Pressing the home button takes you back to the start screen from any menu.
Pressing the return button takes you back one level or to the previous page in the modules
(boiler, hot water tank, buffer, solar, heating circuit, hydr. compensator, net pump, zone
valve, ext. demand).
Summary of Contents for firematic PELLET 120
Page 1: ...OPERATING INSTRUCTIONS Wood chips pellets heating system firematic PELLET 120 201 ...
Page 84: ...15 Annex 84 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 85: ...Annex 15 85 Hydraulic recommendation 2 ...
Page 86: ...15 Annex 86 15 2 Solar module Program 1 ...
Page 87: ...Annex 15 87 Program 2 ...
Page 88: ...15 Annex 88 Program 3 ...
Page 89: ...Annex 15 89 Program 4 ...
Page 90: ...15 Annex 90 Program 5 ...
Page 91: ...Annex 15 91 Program 6 ...
Page 92: ...16 Notes 92 16 NOTES ...
Page 93: ...Notes 16 93 ...