Maintenance schedule
11
77
Item
Procedure
Fire extinguisher
Check fire extinguisher securing and seal
as well as hose and nozzle (according to
national standard)
Sensor barrier
Demount intermediate hopper cover
Unscrew revision cover
Clean sensors on the inside of the
intermediate hopper with soft tissue on
the left and right
Ash storage
Ash has to be stored in a non flammable,
air tight container till disposal.
Boiler room
Remove flammable materials, except
wood chips or pellets stored in a
appropriate container, from the operating
room
Fire protection
Check structural fire protection and fire
doors (e.g.: self-locking fire door)