Maintenance schedule
11
79
Flange bearing
(from firematic
130)
Bearing lubricate inside
11.4
Annually inspection
Annual inspection, at least every 3000 operating hours
Item
Procedure
Maintenance
Conduct system maintenance by authorised
personnel
Drives and
motors
Demount intermediate hopper covers
Check
gear
motor
for
abnormal
or
conspicuous running noises by using the
aggregate test
Check gear motor visually for damages and
wear.
Item
Procedure
Flange bearing
(from firematic
130)
Check visually for wear
Lubricate the chain and the bearing at the
outside
retighten worm screw
Burn back
protection device
Demount intermediate hopper cover