Menu navigation and adjustment values
9
39
Term
Description
Unit
Agitator
Displays the condition of the agitator:
If switch on green
➔
Output active.
-
In-/Outputs
1 2 3
4
5 6 7
Ignition element /
ignition heating / fan
Display the state of the Ignition element (ignition heating / fan):
If switch on green
➔
Output active.
-
Lambda probe heating
Indicates the state of the lambda probe heating.
If switch on green
➔
Output active.
%
ID fan
Display of the output of the ID-fan control and display of the currently
measured speed.
%
Under pressure
Indication of the under pressure in the combustion chamber (at under
pressure control or monitoring)
Pa
Secondary air flap
Indication of the secondary air flap control output
%
Primary air fan
Indication of the primary air fan output
%
In-/Outputs
1 2 3 4
5
6 7
Air flap burner
Indicates the output of the air flap burner
%
Heat exchanger
cleaning (HEC)
Indicates the state of the central de-ashing system:
If switch on green
➔
Output active
-
HEC-monitoring
Indicates the state of the sensor of the HEC- monitoring.
If the indicator lamp lights up alternately during operation, the HEC works
correct.
%
Magnetic valve
Indicates the state of the magnetic valve:
If switch on green
➔
Output active
-
Fault E-Filer
Indicates the output of the E-filter
-
fluegas-recirculation
flap
Indicates the output of the fluegas-recirculation flap
%
In-/Outputs
1 2 3 4 5
6
7
Back flow pump
Displays the state of the backflow pump:
If switch on green
➔
Output active.
-
Back flow mixer open
Displays the state of the Backflow mixer:
If switch on green
➔
Output active.
-
Back flow mixer close
Displays the state of the Backflow mixer:
If switch on green
➔
Output active.
-
Output temperature
monitoring control
(TÜB)
Displays the state of the Output temperature monitoring control:
If switch on green
➔
Output active.
-
Temp. monitoring
control storage room
Displays the state of the Output temperature monitoring control storage
room:
If the indicator lamp lights up, the maximum storage room temperature is
exceeded (the storage room temperature control sensor is active).
-
Sum annoyance
Displays the condition of the Sum annoyance:
If switch on green
➔
Output active (active fault).
-
Operating alarm unit
Displays the condition of the Operating alarm unit:
If switch on green
➔
Output active.
-
In-/Outputs
1 2 3 4 5 6
7
Safety temperature
limiter (STL)
Indicates the input of the STL: If the indicator lamp lights up, the STL has
tripped.
-
STL burner
Indicates the input of the safety temperature limiter (STL): If the indicator
lamp lights up, the STL burner has tripped.
-
Burner stop
Indicates the input of the safety temperature limiter (STL): If the indicator
lamp lights up, the STL has tripped
-
Summary of Contents for pelletfire 20/20
Page 1: ...OPERATING INSTRUCTIONS Log wood pellet heating system pelletfire 20 40 ...
Page 90: ...15 Annex 90 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 91: ...Annex 15 91 Hydraulic recommendation 2 ...
Page 92: ...15 Annex 92 15 2 Solar module Program 1 ...
Page 93: ...Annex 15 93 Program 2 ...
Page 94: ...15 Annex 94 Program 3 ...
Page 95: ...Annex 15 95 Program 4 ...
Page 96: ...15 Annex 96 Program 5 ...
Page 97: ...Annex 15 97 Program 6 ...
Page 98: ...16 Notes 98 16 NOTES ...
Page 99: ...Notes 16 99 ...