Menu navigation and adjustment values
74
No. Fault report
Cause of fault
Fault correction
044
LEGIONELLA
PROTECTION.
Tank thermal disinfection active; Tank
will be heated up to 75°C (weekly)
-
045
CHIMNEY SWEEP.
MODE
when starting Chimney clean mode
(see chapter 9.5)
046
MOD.ERR EXT.
if CAN communication to the external
module is interrupted
Check module CAN connection
Check module
✆
- contracting party
047
MOD.ERR INT.
if CAN communication to the external
module is interrupted
Check module CAN connection
Check module
✆
- contracting party
048
MOD.ERR BOILER
if CAN communication to the power
unit is interrupted
Check module CAN connection
Check module
✆
- contracting party
049
DATAERROR
MEMORY
EXTERNAL
Data adjustment error at external
module
✆
- contracting party
050
DATAERROR
MEMORY INTERNAL
Data adjustment error at external
module
✆
- contracting party
051
DATAERROR
MEMORY BOILER
in the event of an error in the
adjustment data of the power unit
(when starting the system)
✆
- contracting party
053
ADDITIONAL FLUE
GAS SENSOR
Additional boiler flue gas temperature
out of range
Check sensor, replace as necessary
Check plug, replace as necessary
Check wiring incl. connections, replace as
necessary
054
EXTERNAL SET
POINT
Ext. No Signal of external requirement
or control (if line monitoring is active)
Check external (additional) control signal
Check plug, replace as necessary
Check wiring incl. connections, replace as
necessary
055
BACK FLOW SET
if the Backflow-temperature in
operation does not exceed 53 ° C
within 2 hours
Function check mixer with mixer motor
Function check pump
Check sensor position
056
SCREED BAKE OUT
Set flow temperature does not reach
the desired flow setpoint temperature
for 3 hours
Function check mixer with mixer motor
Function check pump
Check sensor position
Required heat output to high
057
CHECK DATA
MODUL
if setting value is not within the valid
range when switching on
Restart T-Control
Check boiler parameter
058
CHECK DATA
BOILER
if setting value is not within the valid
range when switching on
Restart T-Control
Check boiler parameter
059
CAN-ID
used CAN-ID must not be used
-
060
INSERTION IN
ACTION
when stoker temperature in operation
exceeds 70 ° C or during ignition
phase in parallel with No.61
Check fuel quality
Check fuel storage room (fuel level)
Clean intermediate hopper level sensor
061
INSERTION NOT IN
ACTION
when stoker temperature in operation
exceeds 70 ° C or during ignition
phase in parallel with No.60
Chimney draught to high
Feeding channel leakage
Check fuel quality
Shortening burn out time
Underrun minimum running time
062
INSERTION
BACKFIRE
Stoker temperature within 30 min. not
under 70°C
Chimney draught to high
Boiler system leakage
Check fuel quality
Shortening burn out time
Underrun minimum running time
✆
- contracting party
063
OPEN BFP
if BFP-Open-Contact is not reached
during activation
Check BFP-motor
Check fuel temperature
Clean intermediate hopper level sensor
Check drive arm
✆
- contracting party
Summary of Contents for pelletfire 20/20
Page 1: ...OPERATING INSTRUCTIONS Log wood pellet heating system pelletfire 20 40 ...
Page 90: ...15 Annex 90 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 91: ...Annex 15 91 Hydraulic recommendation 2 ...
Page 92: ...15 Annex 92 15 2 Solar module Program 1 ...
Page 93: ...Annex 15 93 Program 2 ...
Page 94: ...15 Annex 94 Program 3 ...
Page 95: ...Annex 15 95 Program 4 ...
Page 96: ...15 Annex 96 Program 5 ...
Page 97: ...Annex 15 97 Program 6 ...
Page 98: ...16 Notes 98 16 NOTES ...
Page 99: ...Notes 16 99 ...