11
Description of the menu navigation and adjustment values
34
Betriebsanleitung_pelletfire_Touch_Englisch_V1.2
Term
Description
Unit
Discharge screw
*
Indication of the state of the discharge screw (=room discharge
).
When the indicator lamp lights up fuel is discharged from the storage.
-
Container screw
*
Indication of the state of the container screw.
When the indicator lamp lights up fuel is discharged.
-
Pellets stirrer*
Indication of the state of the pellets stirrer:
When the indicator lamp lights up fuel is discharged with the pellets
stirrer.
-
Outputs II
Grate cleaning *
Indication of the state of the Grate cleaning:
When the indicator lamp lights up the grate will be cleaned
automatically.
-
Ignition heating
Indication of the state of the heating ignition
When the indicator lamp lights up the heating will be activated (only by
the start-up) and the fuel will get ignited.
-
Ignition fan
Indication of the state of the fan ignition
When the indicator lamp lights up the fan will be activated (only by
the start-up)
-
Output temperature
control
Indication of the state of the temperature control in the storage room:
A lighted indicator lamp signaled a too high temperature in the
storage room
-
Operating alarm unit
The indicator lamp is active if the system is in operation (only in the
operating mode „Heating off“ is the indicator lamp not active).
-
Burner air flap
Indication of the state of the Burner air flap
%
Outputs III
Back flow pump*
Indication of the state of the back flow pump:
When the indicator lamp lights up the back flow pump is in operation.
-
Back flow mixer open*
Indication of the state of the back flow mixer:
When the indicator lamp lights up the back flow mixer is open
-
Back flow mixer close*
Indication of the state of the back flow mixer:
When the indicator lamp lights up the back flow mixer is closed
-
Sum annoyance*
Displays a common alarm
-
Heatexchanger
cleaning*
Indication of the state of the heat exchanger cleaning:
When the indicator lamp lights up the heat exchanger is cleaned
automatically
The interval while the heat exchanger is cleaned is adjusted by the
customer service
-
Outputs IV
Lambda heating*
Indication of the state of the lambda heating:
When the indicator lamp lights up the lambda heating is active.
The lambda heating is in every operating mode (except “Heating off”)
active.
-
ID fan*
Display of the ID
– fan excitation and feedback of the speed.
%
Primary air flap*
Display of the value of the primary air flap
%
Secondary air flap*
Display of the value of the secondary air flap
%
MODUL
Boiler
Buffer
Hot water tank
Heating circuit
Time mode
Solar
Hydr.compensat
Net pump
Zone valve
Ext. requirement
addit. boiler
Summary of Contents for pelletfire
Page 1: ...Operating instructions Log Wood Pellet heatingsystem pelletfire 20 40 ...
Page 86: ...16 Annex 86 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Hydraulic recommendation 2 ...
Page 87: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 87 16 2 Solar module Program 1 ...
Page 88: ...16 Annex 88 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 2 ...
Page 89: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 89 Program 3 ...
Page 90: ...16 Annex 90 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 4 ...
Page 91: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 91 Program 5 ...
Page 92: ...16 Annex 92 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 6 ...
Page 93: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 93 17 NOTES ...
Page 94: ...17 Notes 94 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 ...
Page 95: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 95 ...