Description of the menu navigation and adjustment values
11
Betriebsanleitung_pelletfire_Touch_Englisch_V1.2
35
Term
Description
Unit
Inputs I
Grate closed
Indication of the state of the Grate closed:
When the indicator lamp lights up the tipping grate is closed
-
Tank empty
Indication of the state of the Tank empty:
If the indicator lamp lights up, the intermediate hopper is empty
-
BFP closed
Indication of the state of the back burn flow protection (BFP):
If the indicator lamp lights up, the back burn flow protection is closed
-
BFP open
Indication of the state of the back burn flow protection (BFP):
If the indicator lamp lights up, the back burn flow protection is open
-
Temp. control storage
room
Indication of the state of the Temperature Control in the storage room:
If the indicator lamp lights up, the temperature in the storage room
exceeded the permissible maximum temperature (the storage room
temperature control sensor is active.
-
Additional input
Indication of the state of the Additional input:
If the indicator lamp lights up the additional input is active
An additional input can be e.g. a CO-indicator, a system pressure
control and so on.
-
Inputs II
Motor prot. discharge
screw
Indicates the status of the stoker screw motor and the ash screw motor
protection
If the indicator lamp lights up, the motor protection (stoker- or ash
screw) has released.
-
Burner stop
Indication of the state of the system:
When the indicator lamp lights up the burner has stopped over the
digital input.
-
Ash door opened
Indication of the state of the ash door:
When the indicator lamp lights up the ash door is open
-
Vacutrans flap opened
Indication of the state of the Vacutrans flap opened:
When the indicator lamp lights up fuel is blocked in the back burn flow
protection (Cover limit switch active)
-
Barrier level available
Indication of the state of the barrier level:
When the indicator lamp lights up a barrier level is available, i.e. it is
enough material in the stoker screw channel available
-
Inputs III
Heatexchanger
cleaning
*
Indication of the state of the heat exchanger cleaning:
When the indicator lamp lights up the heat exchanger is cleaned
automatically.
The interval while the heat exchanger is cleaned is adjusted by the
customer service.
-
STL
Indication of the state of the safety temperature limiter (STL):
When the indicator lamp lights up the safety temperature limiter was
activated, i.e. the boiler turned off when a boiler temperature above
95°C was reached.
-
MODUL
Boiler
Buffer
Hot water tank
Heating circuit
Time mode
Solar
Hydr.compensat
Net pump
Zone valve
Ext. requirement
addit. boiler
Summary of Contents for pelletfire
Page 1: ...Operating instructions Log Wood Pellet heatingsystem pelletfire 20 40 ...
Page 86: ...16 Annex 86 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Hydraulic recommendation 2 ...
Page 87: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 87 16 2 Solar module Program 1 ...
Page 88: ...16 Annex 88 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 2 ...
Page 89: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 89 Program 3 ...
Page 90: ...16 Annex 90 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 4 ...
Page 91: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 91 Program 5 ...
Page 92: ...16 Annex 92 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 6 ...
Page 93: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 93 17 NOTES ...
Page 94: ...17 Notes 94 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 ...
Page 95: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 95 ...