Terms and definitions
8
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
61
Position
Term
Display- /
Setting value
Description
Figure 7.25
Ignition heating*
Display- / Setting
value
Indication of the state of the heating
ignition:
When the indicator lamp lights up
the heating will be activated (only by
the start-up) and the fuel will get
ignited
Ignition fan*
Display- / Setting
value
Indication of the state of the fan ignition:
When the indicator lamp lights up
the fan will be activated (only by the
start-up)
ID
– fan*
Display- / Setting
value
Display of the ID
– fan excitation and
feedback of the speed
Figure 7.26
Back flow pump*
Display- / Setting
value
Indication of the state of the back flow
pump:
When the indicator lamp lights up
the back flow pump is in operation
Back flow mixer open*
Display- / Setting
value
Indication of the state of the back flow
mixer:
When the indicator lamp lights up
the back flow mixer is open
Back flow mixer close*
Display- / Setting
value
Indication of the state of the back flow
mixer:
When the indicator lamp lights up
the back flow mixer is closed
Output temperature control*
Display- / Setting
value
Indication of the state of the temperature
control in the storage room:
A lighted indicator lamp signalled a
too high temperature in the storage
room
Sum annoyance*
Display- / Setting
value
Alarm output, Display by certain errors
(see chapter 9, Column Sum
annoyance)
Operating alarm unit*
Display- / Setting
value
The indicator lamp is active if the system
is in operation (only in the operating
mode „Heating off“ is the indicator lamp
not active)
Summary of Contents for pelletstar 10
Page 1: ...Operating instructions pelletstar 10 60 ...
Page 92: ...13 Notes 92 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 13 NOTES ...
Page 93: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 93 ...
Page 94: ...13 Notes 94 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 ...
Page 95: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 95 ...