Terms and definitions
8
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
73
8.6
Solar module
Position
Term
Display- /
Setting value
Description
Figure 7.58
Figure 7.70
Figure 7.76
Collector flow temperature
Display value
Display of the collector flow temperature
in °C
Collector backflow temp.
Display value
Display of the collector backflow
temperature in °C
Tank 1 temperature
Display value
Display of the tank temperature of tank 1
in °C (e.g.: Hot water tank, buffer)
Figure 7.70
Figure 7.76
Tank 2 temperature
Display value
Display of the tank temperature of tank 2
in °C (e.g.: Hot water tank, buffer)
Figure 7.59
Figure 7.65
Figure 7.71
Figure 7.77
Actual yield [W]
Display value
Indication of the current energy yield
Daily yield [Wh]
Display value
Indication of the energy yield on one day
(from 0
– 24h)
Total yield [Wh]
Display value
Indication of the total energy yield
measured
Collector pump
Display value
Indication of the state of the collector
pump (ON/OFF)
Figure 7.65
Figure 7.77
Loading pump
Display value
Indication of the state of the loading
pump (ON/OFF
only visible, when
program number 2 is chosen)
Figure 7.71
Figure 7.77
Switching valve
Display value
Indication of the state of the switching
valve (ON/OFF
only visible, when
program number 3,4 or 5 is chosen)
Figure 7.60
Figure 7.78
Program number
Display value
(Difference of the individual programs
obvious in chapter 7.10.6
– starting on
page 38)
Antifreeze
Setting value
Outside temperature setting (when this
temperature is reached, the solar pump
will be switched on)
Flow rate
Setting value
Flow rate setting for calculating solar
output resp. for calculating the yield
Rotation speed control
Setting value
Activation of speed regulation
Min. rotation speed
Setting value
Min. rotation speed setting (20-100%)
Must value
Setting value
is used as a must value for the rotation
speed.
Control difference
Setting value
is used as actual value for the control;
the control difference is defined of the
average value from (flow + back flow
–
difference 1/2)
Figure 7.61
Figure 7.73
Figure 7.79
Pump trigger
Setting value
Setting the release temperature for solar
pump
Tank 1 must temperature
Setting value
Must temperature of tank 1
Difference 1
Setting value
Difference between collector and tank 1
Tank 1 max. temperature
Setting value
Max. temperature of tank 1
Summary of Contents for pelletstar 10
Page 1: ...Operating instructions pelletstar 10 60 ...
Page 92: ...13 Notes 92 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 13 NOTES ...
Page 93: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 93 ...
Page 94: ...13 Notes 94 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 ...
Page 95: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 95 ...