Fault reports and their correction
9
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
83
Fault reporting on the
display
Possible cause?
Suggestions for rectifying
Sum
annoyance
F: BLOCKING PROTECTION
Blocking protection activated
for buffer storage tank pump
Buffer
storage
tank
pump
triggered for 10 s approx.
Display only, no action
required
FAULT 42
F: LEGIONELLA
PROTECTION
Thermal disinfection in storage
tank activated-Storage tank will
be heated to75°C
Display only, no action
required
FAULT 44
F: CHIMNEY SWEEP. MODE. Chimney
sweep
function
activated
Display only, no action
required
FAULT 45
F: MOD.ERR EXT.
Error in communication via
CAN 2 with an external module
Contact your specialist
installer
FAULT 46
F: MOD.ERR INT.
Error in communication via
CAN 1 with an internal module
Contact your specialist
installer.
FAULT 47
F: MOD.ERR BOILER
Error in communication with the
boiler module
Contact your specialist
installer
FAULT 48
F: DATAERROR MEMORY
EXTERNAL
Error in the adjustment data in
an external module
Contact your specialist
installer.
FAULT 49
F: DATAERROR MEMORY
INTERNAL
Error in the adjustment data in
an internal module
Contact your specialist
installer.
FAULT 50
F: DATAERROR MEMORY
BOILER
Error in the adjustment data in
the boiler module
Contact your specialist
installer.
FAULT 51
F: CLAMPING UNIT
Sensor on the clamping unit
defective
or
break in sensor cable
or
plug not inserted correctly
Contact your specialist
installer.
FAULT 52
F: ADDITIONAL FLUE GAS
SENSOR
Flue gas temperature of the
additional boiler does not fit.
Control the flue gas
temperature
of
the
additional boiler
FAULT 53
F: EXTERNAL SET POINT
Sensor at external temperature
defective
or
break in sensor cable
or
plug not inserted correctly
Renew the sensor
FAULT 54
F: BACK FLOW SET
Back flow set temperature
could not be
reached
in
operation
Control the back flow set
X
FAULT 55
F: SCREED BAKE OUT
Fault in the screed bake out
process.
Flow-must
temperature
could
not
be
achieved.
Control the flow must
temperature
FAULT 56
F: CHECK DATA MODUL
A module parameter is not in
the specified range.
Control
the
module
parameter
FAULT 57
F: CHECK DATA BOILER
A boiler parameter is not in the
specified range.
Control
the
boiler
parameter
FAULT 58
F: INSERTION IN ACTION
Feed screw temperature too
high when
in operation
Contact your specialist
installer.
X
FAULT 60
F: INSERTION NOT IN
ACTION
Feed screw temperature too
high when
out of operation
Contact your specialist
installer.
FAULT 61
F: INSERTION BACKFIRE
Feed screw temperature still
too high after 15 minutes safety
time
Contact your specialist
installer.
X
FAULT 62
Summary of Contents for pelletstar 10
Page 1: ...Operating instructions pelletstar 10 60 ...
Page 92: ...13 Notes 92 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 13 NOTES ...
Page 93: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 93 ...
Page 94: ...13 Notes 94 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 ...
Page 95: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 95 ...