T-CONTROL
9
25
9.6
Switching the boiler on and off (Chimney sweeping function)
SWITCH-ON
SWITCH-OFF
Navigation:
Navigation:
Screen:
Screen:
By pressing the button:
By pressing the button:
the boiler will be switched on.
the boiler will be switched off.
the boiler will switch off, remains
off and the previous page will be
displayed.
the boiler remains on and the
previous page will be displayed.
Note:
Note:
The system can only be switched on if there are no
errors that prevent it from starting.
The boiler will switch to
the operating condition “burn
out phase” (except “cold start” or “ready”). When
switching off during cold start, the cold start is ended
and then changes to the burnout phase. This
prevents impermissibly high amount of fuel in the
combustion chamber.
CHIMNEY SWEEPING FUNCTION
Navigation:
Screen:
If “chimney sweeping function” is
active, the remaining time can be
raised in 5 minutes steps by
pushing the
-button.
Raises
the
remaining
time
(chimney sweeping mode) by
5 minutes steps.
After pressing the chimney sweeping symbol, the
boiler can also be switched off.
Summary of Contents for pelletstar CONDENSATION 10
Page 1: ...OPERATING INSTRUCTIONS Pellet boiler pelletstar CONDENSATION 10 60 ...
Page 86: ...15 Annex 86 Hydraulic recommendation 2 ...
Page 87: ...Annex 15 87 15 2 Solar module schematic representation Program 1 ...
Page 88: ...15 Annex 88 Program 2 ...
Page 89: ...Annex 15 89 Program 3 ...
Page 90: ...15 Annex 90 Program 4 ...
Page 91: ...Annex 15 91 Program 5 ...
Page 92: ...15 Annex 92 Program 6 ...
Page 93: ...Notes 16 93 16 NOTES ...