3
of 8
Diagram 2
Door Preparation
Diagram 3
Insert Lock Body
3A:
FRONT
3B:
BACK
Mounting
1.
LOCATE the 6" x 1" [150 x 25 mm] lock
cutout on the door.
Diagram 2.
2.
INSERT the KS200/KS2100 Lock Body
(A) into the 6" x 1" [150 x 25 mm] cutout.
Make sure the unit bottom tabs grab
the back of the wall.
Diagram 3.
3.
ENSURE KS200/KS210 Lock Body (A)
is flush against the mounting surface
to ensure the tamper switch on the
back of the device is fully depressed
and operating correctly.
Diagram 4.
4.
CONNECT the female, 10-position
Hirose connector on the Lock Interface
Cable (B) to the back of the KS200/
KS210 Lock Body (A).
Diagram 5.
NOTE:
ENSURE that the Lock Interface
Cable (B) is not pinched or exposed prior to
attaching the Rear Mounting Bracket (C).
• (OPTIONAL) REMOVE the 4-Pin
and 8-Pin Molex Connectors from
the end of the Lock Interface
Cable (B) when the ElectroLynx
Interface Cables are NOT utilized.
• GO TO Optional Quick Connect Guide
(CONNECTIONS & WIRING) when
using ElectroLynx Interface Cables.
5.
(OPTIONAL) CONNECT the Plug-In
RS-485 Auxiliary Output Adapter
Cable to extend control to other
compatible locking devices.
NOTE:
Compatible with KS210
OSDP RS-485 models only.
6.
(OPTIONAL) CONNECT the Plug-In
External DPS Adapter (I)
Diagram 6
to extend the Tamper/Locked
State Monitoring to include other
EXTERNAL normally open switches
that can be wired in series to monitor
additional doors or panels.
NOTE:
The DPS signals a secure state
(closed) when the handle is resting
in it the locked/latched position.
External DPS/Tamper rated for use up
to 100 mA at 30 VDC resistive load.
1"
[25.4mm]
6"
[150mm]
Diagram 4
Tamper Switch
NOTE:
If the tamper switch is NOT fully
depressed, the Tamper/Locked State/DPS
contact will report as a non-secure status.
Tamper
Switch
Diagram 5
Connect Lock Interface Cable (B)
Integrated Handle
Locked State
Monitoring (SPST-NO)
Plug-In External
DPS Adaptor (3)
(Optional)
External Monitoring of
Doors/Panels with
Normally Open (SPST-NO)
Switches Sold Separately
Diagram 6
Connect (Optional) External DPS (I)